6.3.2 Layout of the fully automatic oven cleaning system
Cleaning agent and rinse aid
Use only the cleaning fluids specified here to clean the combi oven.
NOTICE Damage caused as a result of improper use of cleaning agents will invalidate any warranty
claims.
The following table shows the approved cleaning agent and rinse aid:
Name
Product
Label color
Cleaning agents
ConvoClean forte
red
Rinse aid
ConvoCare
green
Layout of the fully automatic oven cleaning system (6.06/6.10/10.10 mini)
The following diagram shows the layout of the fully automatic oven cleaning system:
1
5
3
2
4
No.
Name
Color coding
1
ConvoCare rinse aid canister
green (label)
2
Delivery tube for rinse-aid suction nozzle
green (tube)
3
D10 wire clip
-
4
Extractor tube for cleaning agent suction nozzle
red (tube)
5
ConvoClean forte cleaning agent canister
red (label)
F
Appliance connector for rinse aid supply
green (lettering)
G
Appliance connector for cleaning agent supply
red (lettering)
Installation location for the cleaning-agent and rinse aid canisters (6.06/6.10/10.10 mini)
Install the canisters as follows:
■
The canisters should be located for easy access beside the appliance on a flat surface.
■
The canisters must not be positioned above the level of the surface on which the appliance stands.
■
The level of the surface on which the canisters stand must not lie more than 1 m below the tube
connections on the appliance.