background image

 

 

Installation, Servicing and User Instructions for 
LD64 OVENS 

CAUTION: Read the instructions before using the appliance. 
 

Important Installation Information 

The installer must ensure that installation of the unit(s) is in conformity with regulations in force at the 
time. For the UK, particular attention requires to be paid to:- 

BS7671 IEE Wiring Regulations 
Electricity at Work Regulations 
Health and Safety at Work Act 
Fire Precautions Act 

The unit has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the 
voltage stated on the data plate. 
 

WARNING: THIS APPLIANCE MUST BE EARTHED! 
 
Preventive Maintenance Contract 

In order to obtain maximum performance from the equipment, we would recommend that a 
maintenance contract be arranged with 

AFE Serviceline

. Visits may then be made at agreed intervals to 

carry out adjustments and repairs. A quotation for this service will be provided upon request. Contact 
Serviceline as detailed below:- 

Tel: 01438 363 000       Fax: 01438 369 900 

 
     WEEE Directive Registration No. WEE/DC0059TT/PRO 

At end of unit life, dispose of appliance and any replacement parts  in a safe manner, via 
a licenced waste handler. 
Units are designed to be dismantled easily and recycling of all material is encouraged 
whenever practicable. 

Falcon Foodservice Equipment 
Wallace View, Hillfoots Road, Stirling. FK9 5PY 
Tel: 01786 455 200       Fax: 01786 469 454 
e-mail: [email protected]                                    

 

 

    

T100321 Ref. 8

 

 
 
 
 
 
 

Содержание LD64

Страница 1: ...Preventive Maintenance Contract In order to obtain maximum performance from the equipment we would recommend that a maintenance contract be arranged with AFE Serviceline Visits may then be made at agreed intervals to carry out adjustments and repairs A quotation for this service will be provided upon request Contact Serviceline as detailed below Tel 01438 363 000 Fax 01438 369 900 WEEE Directive R...

Страница 2: ...ts Poor combustion caused by lack of cleaning Lubrication of moving parts Lubrication of gas cocks Cleaning adjustment of pilots Correction of gas pressure to appliance Renewing of electric cable ends Replacement of fuses Corrosion caused by use of chemical cleaners Electrical Safety and Advice Regarding Supplementary Electrical Protection Commercial kitchens and foodservice areas are environments...

Страница 3: ...r unit upon the LD62 and LD64 ovens it is recommended that units which carry liquids i e fryers and bains marie are secured as follows Remove oven outer back panel Remove oven crown plate Position unit s which require to be secured upon the oven Secure hob unit s to oven through side flange centre holes into the threaded inserts in the base s of the hob unit s Use fixings provided packed separatel...

Страница 4: ...or coloured GREEN or GREEN YELLOW NEUTRAL to terminal marked N or coloured BLACK LIVE to terminal marked L or coloured RED Units which receive power from a plug adaptor or distribution board must be individually protected by a fuse with an appropriate rating see technical information Any replacement supply cable must be 1 5mm2 cord code designation 245 IEC 57 CENELEC H05 RN F For internal connecti...

Страница 5: ...helves These are designed to prevent being pulled out accidentally To remove a shelf pull forward to stop position and tilt up When replacing a shelf insert with rail stop to the rear There are six runner positions For even shelf cooking distances between trays should be consistent Shelf combinations with regard to position should be 2 4 6 from the top or 3 6 A typical shelf load may be 12 x 56g 2...

Страница 6: ...ich secure handle to door and remove handle Replace in reverse order Door Catch Remove door as detailed above Drill out pop rivets on the door edges and separate door halves Drill out catch rivets and remove catch Replace in reverse order FUNCTIONAL COMPONENTS Thermostat Remove crown plate or counter model Refer to Siting section Remove control knob Remove electrical connections noting the positio...

Страница 7: ...le fixings and lift from keyhole slots Undo element fixings from inside the oven Withdraw elements take care not to pull the wires Undo element connections and replace in reverse order Mains Power Cable Remove outer back Remove cable from terminal block Replace in reverse order and ensure cable is pulled taught and tightened in a manner which securely grips the cable within the fitting Terminal Bl...

Страница 8: ...LD64 WIRING DIAGRAM ...