6.1.4 Converting the electrical supply to a single-phase supply (6.06 mini)
Objective
To convert the electrical supply from 3N~ 400V 50/60Hz (3/N/PE) to 1N~ 230V 50/60 Hz (1/N/PE).
Requirements
Check that the following requirement has been met:
■
The connection point of the appliance is disconnected from the customer power supply and protec‐
tive measures taken to ensure the power cannot be switched on again.
Converting to a single-phase supply (1N~ 230V)
Follow the steps below to convert the appliance to a single-phase supply:
Step
Action
Illustration
1
Insert the jumper as shown in the circuit dia‐
gram (page 2).
2
Stick the relevant label on the type plate.
3
After conversion, the injection times for the
steam generator must be corrected.
Contact an authorized service company or
the manufacturer about correcting the rele‐
vant operating parameters.
Service values for the moisture setting
The following table shows the Injection Times operating parameters for different supply ratings:
ID
Description
3N~ 400V 50/60Hz (3/N/PE)
1N~ 230V 50/60 Hz (1/N/PE)
13
Quick-steam
12 sec
6 sec
14
Steaming
25 sec
14 sec
15
Combi-steam
12 sec
6 sec