Connection diagram (6.10 mini 2in1)
The following diagram shows the drain installation system:
1
2
5
4
3
5% (3°)
Item
Meaning
Explanation
1
Drain connection
■
On the rear of the combi oven, connection drawing: point C
2
Safety overflow
■
Underneath the combi oven, connection drawing: point M
■
Used to drain away water in the event of a fault (blockage).
3
Waste pipe DN 50
■
Minimum internal diameter = 46 mm
■
Slope 5% (3°)
4
Waste trap / Funnel waste
trap
■
Blocks smells
5
Drain pipe DN 50
■
Minimum internal diameter = 46 mm
■
Slope 5% (3°)
Fitting the drain connection
Follow the steps below to provide the water drain for your combi oven:
Step
Action
1
Connect the appliance as shown in the connection diagram.
Reducing the cold water consumption
To reduce the amount of cold water that is used, the temperature above which the condenser is
cooled with water can be adjusted. A maximum value of 80 °C is permitted. This is the maximum tem‐
perature of water allowed to be released into the waste-water system.
This adjustment can be carried out by an authorized service company or the manufacturer.
Condenser Temperature operating parameter
The following table shows the Condenser Temperature operating parameter (temperature above
which the condenser is cooled with water) and its range of values:
ID
Description
Factory setting [°C]
Range [°C]
8
Condenser tempera‐
ture
68
50 - 95
6 Installation
Installation manual
77