Regular tests and operational leakage current values
It is compulsory to test the appliance regularly in accordance with the recognized codes of practice
Calibrated meters must be used for the electrical testing in order to perform the stipulated measure‐
ments of protective conductor resistance, insulation resistance, protective conductor current / leakage
current (see also Individual electrical test on page 86 in the chapter 'Putting into service').
The values measured in these compulsory regular tests must be compared and assessed against the
operational leakage current values specified by the manufacturer. The leakage current values are lis‐
ted under Technical data on page 92 in the 'Electrical connected load ratings' table.