6.2.3 Test the water quality
Materials required
You will need the following materials:
■
1 sample container for taking samples
■
1 conductivity meter (part no. 3019007)
■
Analysis kit for measuring general hardness and carbonate hardness, including two analysis con‐
tainers (part no. 3019010)
■
Wrench for unscrewing the catches on the suction panel
■
Personal protective equipment: Protective gloves
Test the water quality
Follow the steps below to check the water quality of the cold water and soft water:
Step
Action
Illustration / Further details ...
1
Measure the ppm or the conductivity.
1µS/cm = 0.6 ppm (physical assumption)
2
Measure the general hardness (GH).
Pour 5ml of sampled water into an analysis container
for each water type. One drop of the analysis fluid is
equivalent to 1°dH.
No. Test time
Color of test solution
1
Analysis liquid
Green
2
Start of test
Colorless / orange
3
End of test
Green
3
Measure the carbonate hardness (KH)
Pour 5ml of sampled water into an analysis container
for each water type. One drop of the analysis fluid is
equivalent to 1°dH.
No. Test time
Color of test solution
1
Analysis liquid
Orange
2
Start of test
Colorless / purple
3
End of test
Orange
4
Analyze the result.
The measurements must lie within the target range.
Requirements relating to the wa‐
6 Installation
Installation manual
75
Содержание Convotherm OES mini easyTouch
Страница 1: ...Combi oven Read instructions before use OES mini easyTouch Installation manual Original ENG ...
Страница 2: ......