11
Tip:
When modifying the opening and closing indents, pay attention to observe
whether the position of the limit pressure bar and the limit adjusting bolt is sufficient,
and use a 4mm Allen wrench to adjust the position of the bolt appropriately.
4.3.5. Remote controller learning
Sub-menu
Remarks
5.1 How to match
code
Press the setting button to enter the learning state of the remote
controller, and press any buttons of the remote controller to
learn. Users can learn up to 60 remote controllers
5.2 How to clear
code
Press the Setting button to invert the color of the +- symbol on
the screen, and press ▲ and ▼ at the same time to clear the
code of all remote controllers.
4.3.6. RS485 setting
Sub-menu
Defaults
Range
Remarks
6.1 Address
1
0-255
When RS485 is online, the host is set
to 0, and the slave is set to 1. When it
is connected to the host computer,
1-255 can be set.
6.2 Baud Rate
19200
9600/19200
19200 baud rate is a multi-functional
communication protocol; 9600 is
compatible with the protocol of old
DZ5 control board.
Notice:
please contact the manufacturer for detailed communication protocol.
4.3.7. Auto-closing function
Defaults
Range
Remarks
OFF
0-255, 0 is OFF auto-closing time when no vehicle is passing. Unit: