20
Menu Function
Defaults Range Remark
H-05 Motor rotation direction 2
2-3
2: Rotation direction for
left-installed.
3: Rotation direction for
right-installed.
H-09 Reset
0
0-255
5: clear remote controller
10: reset
H-35
Manually learn
horizontal limit
no
no
Manually learn horizontal
limit
H-38
The motor applies force
in the closing direction
after closing to limit
1
0-1
0: On
1: Off
4.9. "Advanced Menu" Command Explanation:
H-05 Motor rotation direction
The rotation direction of horizontal motor is related to the left-installed or
right-installed of the cabinet, and the rotation direction of the motor needs to be set
correctly according to the fixed direction of the cabinet. The left-installed of the
cabinet is set to 2, the right-installed of the cabinet is set to 3.
H-09 Reset
This option has two functions, clearing the remote control and restoring factory
settings. In order to prevent misoperation, it needs to set a specific value before
pressing "
" button to complete the operation.
5: Clear all learned remote controller of the 3-wire radio receiver of the slave motor.
10: Restore factory settings, restore the set value to the default value, and clear all the
learned remote controls at the same time.
H-35 Manually learn horizontal limit
After entering this option, the LED first displays L-00, and after the horizontal motor
of the barrier gate finds the mechanical blocking position in the open direction, the
buzzer makes a beep, the LED changes to display L-01, and the motor stops. At this
time, it is necessary to manually learn the horizontal opening to limit position and
closing to limit position. First, press and hold the "
▼
/-" button and do not release it,
move the boom holder to the closing direction until the shaft is in the required
opening position (slightly move, reserve a certain space, so that it will not hit when
the barrier gate is normally opened when it reaches the mechanical blocking point),
release the button and press the "
" button to confirm the opening to limit