background image

23

learning failed

does not match the
receiver
The sequence of buttons
on the remote controller
is incorrect

Confirm whether it is the original
remote controller

The vertical motor can
move,

but

the

horizontal motor can’t
move

Enter the menu state of
horizontal motor (slave
motor)

Exit the menu

There is metal impact
sound when the barrier
opens to up limit
position

The value of Fe-09 on
the slave motor is too
small, and the reserved
buffer space is small

Increase the value of F-09
appropriately

The open deceleration
angle of the slave motor
F-02 is too large

Reduce the value of F-02

The metal impact
sound of horizontal
closing is too large
after the barrier open to
limit position

The closing deceleration
angle of the slave motor
F-03 is too small

Increase the value of F-03

Boom

down

limit

position speed of the
slave motor F-07 is too
large

Reduce the value of F-07

6. Warranty and Service Items

6.1. Free service is offered for component parts in one year warranty time. (not
includes the barrier boom or remote)
6.2. Lifetime service with charge accordingly.
6.3. Technical questions are supported.
6.4. The below items and situations are not included in the range of free service:
6.4.1. The user does not follow the instruction and cause any damage of the product.
6.4.2. The power supply is not stable, over the range of permitted voltage or not
accordant to safety electric using standard.
6.4.3. The user installs or uses the product in wrong methods, cause damage to the
appearance of product.
6.4.4. Natural disaster causes damage to the product.
6.4.5. Warranty time is over.

Содержание DC24V

Страница 1: ...I DC Variable Frequency 3D Barrier Gate SCB02 DC24V Manual V1 0 1...

Страница 2: ...ead this manual carefully before using the equipment and strictly follow it during use Please keep the manual properly after reading Operating Environment Requirements Please transport use and store t...

Страница 3: ...anations 4 4 2 Controller Parameter Setting of Master Motor 6 4 3 Regular Menu Command List of Master Motor 6 4 4 Advanced Menu Command List of Master Motor 12 4 5 Controller Parameter Setting of Slav...

Страница 4: ...le to stop at any position in three dimensional space no longer limited height problem 1 1 7 Double protection one drive failure will not affect the other drive and the barrier gate can still operate...

Страница 5: ...4 Motor power up and down power 180W horizontal power 60W 1 2 5 Relative Humidity 30 80 No condensation 1 2 6 Distance of remote control L 30M 1 2 7 Running Speed 0 3 seconds MAX 1 2 8 MTBF 8 000 000...

Страница 6: ...on the ground with 4 sets M16 150 expansion bolts At the location where the cabinet is installed the barrier foundation should be made according to the site conditions and the cast in place foundatio...

Страница 7: ...tem Explanation Wire Control Interface This interface is available for parking system also available for external controller to control barrier gate UP Short circuit UP and GND Down Short circuit Down...

Страница 8: ...modes via option 4 of the advanced menu DC12V Power Output Provide 1A current output available for radar or small light strips Interface for R G lights Available to connect with R G lights to indicate...

Страница 9: ...used to display the information of the slave motor of the barrier gate such as the working status parameters menu items 4 2 Controller Parameter Setting of Master Motor Long press button for 2 second...

Страница 10: ...he angle at which the boom enters a low speed area in the opening process if the boom shakes after it is opened in place users can reduce this value 1 5 End Speed 8 1 50 6 8 The minimum speed at which...

Страница 11: ...ter it is closed in place users can increase this value 2 4 Angle of Low speed Area 0 0 45 0 The angle at which the boom enters a low speed area in the closing process if the boom shakes after it is c...

Страница 12: ...ed that chapter 1 5 set until it is opened in place If the value is 90 the function is invalid If the boom shakes after it is opened in place users can reduce this value appropriately Chapter 2 4 has...

Страница 13: ...when the barrier gate is installed under an eaves please select the Find down limit only mode 4 2 Manual learning f up and down Limit None operate according to the prompts on the screen In manual mod...

Страница 14: ...clear code Press the Setting button to invert the color of the symbol on the screen and press and at the same time to clear the code of all remote controllers 4 3 6 RS485 setting Sub menu Defaults Ran...

Страница 15: ...e sensitivity is the smaller it is the higher the sensitivity Unit millisecond 4 3 10 Restore factory defaults press the setting button to invert the color of the symbol on the screen and press and at...

Страница 16: ...ier gate closes at down limit position users can increase this value appropriately to get some force 3 2 Motor type 129 Rotates Forward 129 Forward Reverse CB03 Forward Reverse It is used for matching...

Страница 17: ...sed when boom falls down the signal during boom falling down and boom at down limit position can be used as R G light signal or used for detecting the barrier gate running status 4 4 5 Buffer time for...

Страница 18: ...op detector to prevent vehicle from being followed by other vehicles and can also prevent the misoperation of the loop detector from triggering the opening of the barrier gate The default value is 5 d...

Страница 19: ...r the boom up speed F 01 Boom Down Speed 100 15 100 90 100 The smaller the value the faster the boom down speed F 02 Boom Up deceleration position 40 10 80 35 45 The angle at which the boom up starts...

Страница 20: ...xplanation F 02 Boom up deceleration position It is used to set the starting position of deceleration in the process of boom lifting up The unit of angle is 0 degrees when the barrier gate is in the h...

Страница 21: ...s speed when boom lifts up If the parameter is set too large the gate lever will shake when it is opened F 07 End speed of boom down The speed for boom moves to down limit The boom will end moving at...

Страница 22: ...te control learning This item is used for the remote control learning of the 3 wire radio receiver of the slave motor It is only used when the main motor fails and the slave motor is used to control t...

Страница 23: ...misoperation it needs to set a specific value before pressing button to complete the operation 5 Clear all learned remote controller of the 3 wire radio receiver of the slave motor 10 Restore factory...

Страница 24: ...ined by F 07 the larger the value the greater the force And the value needs to be set properly and the boom can be closed to limit position without swinging is ok Set the pressure of the boom holder o...

Страница 25: ...s a lot at up limit position Opening speed in up limit position is relatively large Reduce the value of 1 5 in regular menu of the main motor Opening deceleration angle is large Reduce the value of 1...

Страница 26: ...The closing deceleration angle of the slave motor F 03 is too small Increase the value of F 03 Boom down limit position speed of the slave motor F 07 is too large Reduce the value of F 07 6 Warranty a...

Страница 27: ...t 7 4 Remote control distance will be shortened or not work in cases like big object screening battery exhausting extreme weathers 8 Packing List Name Specification Quantity Unit Application Screw Nut...

Отзывы: