- 32 -
The following operating states are indicated:
State
Display
Loading the operating software
The module loads the firmware and gets ready to start
Blue, constantly on
There was an error loading the operating software
The boot process will automatically be restarted
Red for about 5 seconds, then blue again
The boot process for the operating software
The operating software will be started and the control
system will be configured.
Blue, flashing
Wait state
The module is ready for operation and is waiting for a
command.
White, slowly pulsating
Busy
The module is in the initialization phase or is currently
executing a command
White, quickly pulsating
Executing a script
A script is being executed by the control system.
Green, quickly pulsating
Warning
One or more parameters have reached warning limits.
Please check the system’s status via its web interface.
Yellow, quickly pulsating
Command received with no errors
The module has received an error-free command
Green, pulses once
Error carrying out a command
An error has occurred while receiving or executing a
command.
Red, pulses once
Loading the operating software
The module loads the firmware and gets ready to start
Blue, constantly on
Critical fault
An error has occurred (e.g. excess temperature, loss of
communications, etc.). This error must be acknowl-
edged before the module can process new commands
to move.
Red, pulses quickly
Critical software fault
Red, flash code 2x short, long pause
Figure 21: Display of operating state