- 28 -
7.
Once the movements associated with zeroing have finished, for test purposes, you can move the
module via the web interface. For this, select the movement parameters about the adjuster and
then click on the "Move" button.
Important:
The module must be zeroed tob e able to execute movement commands.
8.
Other steps which you should take during the commissioning:
a.
Call up the “Diagnostics” → “System State“ page, to check the module’s supply voltage
b.
On the „Settings” → “Command Interface“ page, select the interface on which your module
is to be operated.
c.
If necessary, on the „Settings” → “Motion Configuration“ page enable automatic zeroing
during startup („Homing on Startup“).
d.
On the „Settings” → “System“ page, create a user with corresponding rights and activate
the web interface’s security function to prevent changes to your setting by unauthorized
persons.
Figure 19: „Manual Control“ configuration page