Part number 550-100-168/0516
124
SlimFit
®
Series 3
COMMERCIAL
CONDENSING
GAS
-
FIRED
WATER
BOILER
—
Boiler Manual
Installation and Gas Boiler Data Collection Sheet
Boiler Model / Series SlimFit
________ /
Series
_______
Date Installed
: ___________________
CP Number
: __________________
Fuel Type: Natural___ LP___
BTU Input: ____________
Was venturi changed? YES___ NO___
Was gas valve throttle adjusted? YES___ NO___
Was gas valve offset adjusted? YES___ NO___
Boiler Settings
Network Settings
Priority 1 Settings
Boiler Model: SlimFit __________
Boiler Address: ____
System Type:
___________
Control Type: _________
Net Max On Time: _____Min
Target Mod Sensor:
___________
High Altitude: YES___ NO___
Net Min On Time: _____Min
Target Adjust:
___________
Max Rate On Net: _____%
Supply Max:
Min Rate On Net: _____%
Supply Min:
! "
Rotation & Sequence
OD Reset Max:
#$"
Sequence Type: ______
OD Reset Min:
'(
Base Rate High: _____%
Volts For Max:
___________ V
Circulator Exercising
Base Rate Low: _____%
Volts For Min:
___________ V
Circulator 1: ON___ OFF___
Boiler Rotation Type: _________
Boost Time:
___________ Mins
Circulator 2: ON___ OFF___
Rotate Frequency: ____Days
System Off Diff:
Circulator 3: ON___ OFF___
Force Lead Rotation: YES or NO
System On Diff:
Boiler Circ: ON___ OFF___
Modbus Settings
Add BLR Diff:
Freeze Protection
Enable: YES___ NO___
Drop BLR Diff:
Circulator 1: ON___ OFF___
Address: __________
Mod Delay Time:
___________ Mins
Circulator 2: ON___ OFF___
Parity Bit: __________
Stabilization Time:
___________ Mins
Circulator 3: ON___ OFF___
Baud Rate: _________bps
Add Delay Time:
___________Sec
Boiler Circ: ON___ OFF___
Stop Bit: YES___ NO___
Drop Delay Time:
___________Sec
Assign Inputs
Max BLR Temp:
Input 1: Priority___ Aux___ OFF___
Boiler On Diff:
Source: TT1 ___ OR 0-10V ___
Boiler Off Diff:
Input 2: Priority___ Aux___ OFF___
Max On Time:
___________ Mins
Input 3: Priority___ Aux___ OFF___
Run Boiler Pump:
YES___ NO___
Run Aux Pump/Output:
YES___ NO___
Max Rate Volts: __________V
Pre Pump:
___________Sec
Min Rate Volts: __________V
Post Pump:
___________Sec
Temp Dependent: YES___ NO___
Max Rate:
___________%
$"#
Min Rate:
___________%
Activate Contact
below setpoint: 1st____ 2nd____
Max System BTUs:
__________ MBUTs
Min Boilers On:
___________
Additional Heat Demand:
1st___ 2nd___ OFF__
Response Time:
___________ Mins
ODT
YES___ NO___