ANGEL EYES REMOVAL
• Remove the grip cheek cover by removing the 6 retaining screws using a
metric 2.5mm A/F Allen key.
• Unplug the battery and solenoid plugs from the PCB
6
.
• Remove the Angel Eyes ribbon cable
7
from the ZIF socket on the
circuit board.
• Remove the Anti double ball covers
1
,
2
,
3
using a metric 2.0 mm
A/F Allen key.
• Remove the Angel Eyes Shields
4
and its sensors
5
from the body.
• Remove the 2 grip frame screws
8
holding the frame to the body using a
suitable 3mm A/F Allen key.
• Remove the grip frame from the body
9
.
NOTE: The Angel Eyes sensor MUST NOT be PULLED out of the body by the
ribbon cable, the sensor MUST be PUSHED out using a suitable blunt
pick from within the body.
IMPORTANT NOTES: For re-assembly of components
• Ensure no wires become trapped between the body and grip frame during
re-assembly.
• Ensure the plugs are located in the correct sockets.
ANGEL EYES
The ANGEL uses a dual optical eye (break beam) system to detect when a ball is
in position and ready to fire.
SERVICE Prior to servicing the Angel Eyes you should carry out the Angel Eye
test to ensure that they are not functioning prior to servicing. See Angel Eye
Test - Right. The Angel Eyes are located under the same cover plates as the
anti double balls and the internal parts can be serviced if necessary. These are
located on either side of the body below the feed tube.
• Using a 2.0mm Allen key, remove the covers
1
.
• Remove the anti double ball assembly
2 3
.
• Carefully remove the rubber protective strap from its location
4
.
• Carefully extract the Angel Eye
5
from its location hole and clean if necessary.
• NOTE: The Angel Eyes sensor MUST NOT be PULLED out of the body by the
ribbon cable, the sensor MUST be PUSHED out using a suitable blunt pick
from within the body.
• Inspect parts and clean if necessary.
IMPORTANT NOTES: For re-assembly of components
• Ensure the anti-double ball is re-located correctly.
• Ensure the spring is located correctly onto the anti-double ball.
• Ensure the cover plates are inserted correctly into the ANGEL body
• Ensure that the Angel Eyes are not moved or trapped.
MAINTENANCE
• Ensure a barrel blocking device is fitted to the ANGEL.
• Ensure the hopper is removed from the ANGEL.
• Ensure that there are no paintballs in the ANGEL.
• Always remove the first stage regulator and relieve all residual gas pressure
from the ANGEL before disassembly.
• The ANGEL can hold a small residual charge of gas, typically 2 shots, with the
first stage regulator removed. Always discharge the marker in a safe direction
to relieve this residual gas pressure.
WARNING
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
• Ensure a barrel blocking device is fitted to the ANGEL.
• Ensure the hopper is removed from the ANGEL.
• Ensure that there are no paintballs in the ANGEL.
• Always remove the first stage regulator and relieve all residual gas pressure
from the ANGEL before disassembly.
• The ANGEL can hold a small residual charge of gas, typically 2 shots, with the
first stage regulator removed. Always discharge the marker in a safe direction
to relieve this residual gas pressure.
WARNING
ADHERE STRICTLY TO THESE
AND ALL OTHER SAFETY
INSTRUCTIONS AND GUIDELINES
2
1
3
4
5
8
8
9
7
6
ANGEL Eyes Service & Removal