MODE FEATURE

• MODE 1: SEMI MODE WITH ANGEL EYES

The ANGEL Semi Mode with Angel Eyes works on the following principles:
•  The Angel Eyes will default to ON whenever the ANGEL is made LIVE via the 

top button located at the rear of the frame.

•  The ANGEL will only fire when a paintball is present.
•  The Angel Eyes system is a break beam system that is not affected by colour, 

shape or finish of paintballs.

•  The ANGEL’s MROF with Angel Eyes ON is limited to whatever MROF setting 

has been entered by the user. When the Angel Eyes are switched OFF the 

MROF is capped at 15.

•  To switch the Angel Eyes OFF the trigger must be held down for 2 seconds.

• MODE 1: SEMI MODE

The ANGEL Semi Mode works on the following principles:
•  In this mode the Angel Eyes are de-activated.
•  The ANGEL will fire whether a ball is present or not.
•  To activate the Angel Eyes after it has been switched off the ANGEL may either 

be switched OFF, then ON again or made SAFE then LIVE.

•  The MROF with the Angel Eyes ON will be at whatever MROF you have 

previously set it to.

• MODE 2: AUTO MODE

The ANGEL Auto Mode works on the following principles:
•  The Angel Eyes will default to ON whenever the ANGEL is switched ON via the 

SAFE LIVE top button located on the rear of the frame.

•  This is full auto and will fire for as long as the trigger is held or until a paintball 

is not present.

• This mode is limited to a MROF of 15 balls per second.
•  This mode will only work with Angel Eyes on and it cannot be deactivated.

• MODE 3: X-BALL 2005

The ANGEL X-ball 2005 3 Shot Burst Mode works on the following principles:
• The Angel Eyes will default to ON.
•  This is a 3 shot bursts mode with the first 3 shot been fired in semi automatic 

only, on the 4th shot a maximum of 3 shots will be added per trigger pull.

•  This mode is limited to a MROF of 15 balls per second when in semi or adding  

shots in.

•  Once the eyes are deactivated the MROF will also have a maximum limit  

of 15 balls per second

• MODE 4:  SEMI LIMITED TO  MROF 15 BALLS/SECOND

• The ANGEL Semi Limited with Angel Eyes works on the following principles:
•  The Angel Eyes will default to ON whenever the ANGEL is made LIVE via the 

top button located at the rear of the frame.

•  The ANGELs MROF with Angel Eyes ON is capped at 15 BPS.
•  To switch the Angel Eyes OFF the trigger must be held down for 2 seconds.
• The ANGELs MROF with Angel Eyes OFF is capped at 15 BPS.
•  The ANGEL will fire whether a ball is present or not.
•  To activate the Angel Eyes after it has been switched off the ANGEL may either 

be switched OFF, then ON again or made SAFE then LIVE.

 

• MODE 5: ACCUM MODE

The ANGEL Accumulator Mode works on the following principles:
• The Angel Eyes will default to ON.
• This is a BPS enhancer that will fire more balls than trigger pulls.
• This mode is limited to a MROF of 15 balls per second.
•  This mode will only work with Angel Eyes on and it cannot be deactivated.

• DEMO MODE

This is a dry firing mode for firing the ANGEL when on display and is designed to 
demonstrate the rate of fire achievable. It should only be used for demonstration 
purposes, as the Angel Eyes feature is reverse functioned so that it cannot fire 
paintballs. Should a paintball be detected it will prevent the ANGEL from firing.

DWELL FEATURE

This controls the valve opening time. Longer Dwell will use more gas and will 
generate more noise but allows the ANGEL to be more tolerant to paintball 
variations. Shorter Dwell will generate less noise and use less gas but will not 
tolerate poor paint quality.

CYCLES FEATURE

This is the ANGEL equivalent of a milometer and will register the total shot count 
that the ANGEL has fired.

ID FEATURE

This is a unique serial number identification that is factory set.

TRIGGER OFFSET FEATURE

This allows the user to set the trigger snubber and can be used to ensure that 
trigger bounce is reduced on triggers that have been set. It should be used to 
eliminate trigger bounce and not used to induce trigger bounce. The level of 
snubbing required will be dependent on the users setting of the mechanical 
adjustments of the trigger. The snubber will be automatically set to the highest 
level of protection on all non semi modes. It is the user’s responsibility to ensure 
that the setting they have selected does not cause accidental discharges.
Level 1 is the maximum trigger damping and increasing the level, reduces the 
damping.

INTERNAL ELECTRONIC LCD MENUS

The ANGEL has a number of features that can be adjusted to suit your individual 
needs. These features can change the performance of your marker and are only 
adjustable via the internal menu. This is to ensure that they pass tournament 
and field operator requirements.
The settings you have selected may be viewed externally but cannot be adjusted 
externally.
The menus can only be accessed when the marker is switched ON and in SAFE.
Remove left hand grip cover screws to expose the circuit board.
Follow the internal menu list diagrams for relevant settings.
The ANGEL has the unique feature that allows you to return to the factory 
defaults settings by pressing and holding the internal menu button for 2 
seconds. 

LCD MENUS

Dual External LCD Menus in Safe Mode: Advanced Menu – Internal Electronic LCD Menus – Factory Default Setting

•  Never adjust your trigger offset so finely  that accidental discharge may occur 

due to shock loads or vibrations.

 WARNING

ADHERE STRICTLY TO THESE 

AND ALL OTHER SAFETY 

INSTRUCTIONS AND GUIDELINES

•  Ensure a barrel blocking device is fitted to the ANGEL.
•  Ensure the hopper is removed from the ANGEL.
•  Ensure that there are no paintballs in the ANGEL.

 WARNING

ADHERE STRICTLY TO THESE 

AND ALL OTHER SAFETY 

INSTRUCTIONS AND GUIDELINES

•  In certain countries local applicable laws or industry standards may mean 

certain modes may not be enabled or allowed. Check with law enforcement 

office, or local professional paintball venue.

 WARNING

ADHERE STRICTLY TO THESE 

AND ALL OTHER SAFETY 

INSTRUCTIONS AND GUIDELINES

Содержание ANGEL G7

Страница 1: ...Connector attachment 5 Macro Line Hose removal and re attachment 5 Loaders Hoppers 5 Soft Nose Bolt Removal Rotor Breech 5 Velocity Adjustment 6 Twist Lock Feed Collar 6 LCD MENUS Basic Menu 7 Menu F...

Страница 2: ...in the breech as high pressure gas will be emitted Do not re the ANGEL with the pull knob in the unlocked position Never look into the barrel or breech area of the ANGEL whilst the marker is switched...

Страница 3: ...r to remain in this state until the ANGEL is made LIVE again by pressing the red button on the back of the grip frame for 2 seconds Supply voltage must be minimum 12V DC maximum 24V DC negative earth...

Страница 4: ...solator switch and then make the ANGEL LIVE by pressing the top button or alternatively make the ANGEL SAFE then LIVE LED INDICATOR STATUS ON THE REAR OF THE FRAME RED CONSTANTLY ON LIVE mode ANGEL EY...

Страница 5: ...ntained or damaged loaders will impair the performance capability of the ANGEL To maximise the performance of the ANGEL WDP recommends only using reliable enhanced feed loaders SOFT NOSE BOLT REMOVAL...

Страница 6: ...orbency TWIST LOCK COLLAR To secure your loader rst ensure the Twist Lock collar is backed off by rotating it counter clockwise Insert the loader into the feed neck and rotate the Twist Lock collar cl...

Страница 7: ...ced viewing menu that allows you to view the full menu for the items you are most likely to use whilst setting up your ANGEL Any menu items that may change the performance of the ANGEL CANNOT be adjus...

Страница 8: ...nnot be deactivated DEMO MODE This is a dry ring mode for ring the ANGEL when on display and is designed to demonstrate the rate of re achievable It should only be used for demonstration purposes as t...

Страница 9: ...IR Send On Off If no signal defaults to Off after 30 sec inactivity ROF MODE Firing Mode No External Access see fig 2 Valve Dwell No External Access see fig 2 Trigger Offset No External Access see fi...

Страница 10: ...OTES SCROLL CONFIRM DIGIT INITIATE TEXT TRIGGER Text Programming can only be completed with the trigger held in and the ANGEL in SAFE Mode CONFIRM TEXT Press Internal to enter TEXT Mode Press again to...

Страница 11: ...4 to 6 until PIN complete Press to confirm PIN If PIN correct ANGEL will enter SAFE Unlocked Mode Or press to clear and return to Step 4 CONFIRM PIN 1 2 3 4 5 6 7 GAME TIMER NOTES FIRST SHOT COMMENCES...

Страница 12: ...external and internal accessible moving parts should be lubricated using light synthetic oil only All threads are metric except gun accessory mountings onto the grip frame which is industry standard 1...

Страница 13: ...eral Assembly Left Hand View Sub Assemblies MAINTENANCE SOLENOID ASSEMBLY TWIST LOCK GATED FEED BATTERY PCB OPTO BOARD GRIP CHEEK MINI REGULATOR END PLUG LPR FLASH TANK GRIP FRAME CONTROL BUTTONS ANTI...

Страница 14: ...14 ANGEL G7 2005 WDP LTD MAINTENANCE Cut Away Views Right Hand Left Hand...

Страница 15: ...rnings given in PROPELLANT AIR NITROGEN SUPPLY Page 4 Remove the mini regulator adjuster screw 1 Remove the mini regulator locking screw 2 Remove the mini regulator end cap 3 by inserting a M4 allen k...

Страница 16: ...p from its location 4 Carefully extract the Angel Eye 5 from its location hole and clean if necessary NOTE The Angel Eyes sensor MUST NOT be PULLED out of the body by the ribbon cable the sensor MUST...

Страница 17: ...Always remove the rst stage regulator and relieve all residual gas pressure from the ANGEL before disassembly The ANGEL can hold a small residual charge of gas typically 2 shots with the rst stage reg...

Страница 18: ...itable metric 4 0mm A F Allen key Insert an M 2 5mm screw or the piston extracting tool optional extra into the brass piston 6 and withdraw slowly Remove the 3 tri active piston spring stack 7 Remove...

Страница 19: ...y is free from damage that may score the bore Ensure you do not damage the exhaust valve guide sealing face Ensure the location hole in the exhaust valve guide is in the correct orientation to the loc...

Страница 20: ...r has been rotated either ensure the angel is gassed up or push the bolt back with a squeegee Remove the breech lock lever by unscrewing the locking screw 3 counter clockwise Remove the screw located...

Страница 21: ...ek cover screws using a suitable metric Allen key Very gently tighten the vernier thumb wheel locking screw IMPORTANT NOTES For re assembly of components There must be suf cient over travel to activat...

Страница 22: ...screw is backed off by rotating counter clockwise It is important that the vernier wheels are inserted in position A shown above wheel 5 with the small magnet towards the back of the ANGEL Wheel 6 wi...

Страница 23: ...ed that it is rotated so that the ON position is as per the diagram in the section SWITCHING ON YOUR ANGEL Page 3 WIRING CONNECTIONS Ensure the ANGEL is de gassed and switched off Remove the left hand...

Страница 24: ...s the barrel bore correct for the paint Use suitable barrel Is the paint swollen cold hot Review your storage of paint Are the Angel Eyes switched on Switching Angel Eyes On 4 Are the Angel Eyes funct...

Страница 25: ...ion to warranty claims shall be borne by the customer Where any valid claim in respect of the ANGEL is based in the quality or condition of the ANGEL or its failure to meet speci cation and such valid...

Страница 26: ...Michigan as excluded modi ed and limited in this warranty 4 Additional Consumer Protection The products are offered for sale for end use in supervised commercial establishments where professional saf...

Страница 27: ...i cation virtual products and on line technical support we recommend that you visit our website www wdp tv YOUR PERSONAL DETAILS Completing these details upon purchase will enable us to help you with...

Страница 28: ...28 ANGEL G7 2005 WDP LTD Notes APPENDICES...

Отзывы: