3 of 11
WX-501-0544 • 01.22
Digital Output
Connector
O1-
O2-
O1+
O2+
I1 +
I1-
I2+
I2-
Digital Input
Connector
In the standard Click513 application, these ports have the following functions:
■
Digital output port 1 –
Used to connect to contact closure device, DMS or other digital I/O systems. This is the
default output for approach 1.
■
Digital output port 2 –
For use with multiple Click 513 devices connected to one DMS. This is the default output
for approach 2.
■
Digital input port 1 –
For use with multiple Click 513 devices connected to one DMS.
■
Digital input port 2 –
For use with multiple Click 513 devices connected to one DMS. Not used in the standard
Click 513 application.
The Click 513 also has two DIP switches on the left side of the module for programming or reprogramming the
unit. For all standard Click 513 applications, the rest of the DIP switches are unused.
Warning.
The sixth switch of DIP switch 1 controls the mode of the device. Make sure that this switch is in the OFF
position. If it gets turned on, the device will enter Program mode and all of the faceplate LEDs will turn off when a
serial connection is made. To exit Program mode, power will need to be cycled on the device.
Configuration Features
There are three banks of LEDs located on the front of the Click 513.
The yellow and red banks of LEDs display submenu selections. See the Operating Modes section of this
document for more information.
The system LEDs (multicolored bank in the middle of the module) have dual functions: they are activity indicators,
reporting system status information, and they are also used in selecting operation modes from the main menu.