background image

7 of 11

WX-501-0544 • 01.22

After you have made configuration changes on a driver and saved it to the Click device, the word “current” will 

appear after that driver to indicate the driver that is currently loaded onto the device.

Note. 

Changing any of the settings on any driver and saving them to the Click device will change those settings 

on all drivers.

The Backups option can be used to read configurations that have previously been saved to file. 

Expert

The Expert driver allows you to configure the Click 513. The driver is divided into two tabs, 

System

 and 

513

.

The 

System

 tab is divided into three subtabs: 

General

Comm

, and 

Autobaud

.

The 

General

 subtab contains information about the device (see the figure and table below).

Setting

Description

Module

Shows the name of the Click device.

Driver

Names the driver you are currently working with.

Description

Shows a description of the device being configured. This is only for your information and does not 

affect the operation of the device.

Location

Displays the location of the device being configured. This is only for your information and does not 

affect the operation of the device.

Serial Number

Displays the serial number of your device.

Содержание Click 513

Страница 1: ...mp If the interval data polled from the SmartSensor HD exceeds the threshold value s the Click 513 will send an alert so that adjustments can be made to help clear the congested roadway such as keepin...

Страница 2: ...program such as Windows HyperTerminal Warning With older versions of the Click 500 series module it is necessary to remove pin 4 from the serial cable to prevent the device from going into Program mo...

Страница 3: ...t side of the module for programming or reprogramming the unit For all standard Click 513 applications the rest of the DIP switches are unused Warning The sixth switch of DIP switch 1 controls the mod...

Страница 4: ...ctive power and RS 485 communication When using multiple Click 513 modules for one DMS the devices can be wired together so that only one Click 513 will be sending an output to the DMS at a time See k...

Страница 5: ...once the desired option is displayed 6 Press the push button again to select the option The mode will now start running Run Mode blue solid Run mode is the first mode presented in the mode selection p...

Страница 6: ...2 114 device via the RS 485 top front port When using a Click 104 you will need to use a gray T bus to isolate communications sent from the RS 485 top front port so they do not collide with communicat...

Страница 7: ...ure the Click 513 The driver is divided into two tabs System and 513 The System tab is divided into three subtabs General Comm and Autobaud The General subtab contains information about the device see...

Страница 8: ...nfigure how the Click device communicates see the figure and table below Setting Description Baud Rate Allows you to change the baud rate at which the device connects to the sensor Flow Control Is use...

Страница 9: ...of seconds that the sensor stores Interval data This field is read only Alert On Time Multiple of Sensor Interval Allows you to enter the number of intervals the Click 513 will use to determine alert...

Страница 10: ...qualify until ALL enabled criteria are met The 513 Output tab contains information about which time zone is configured for the Click 513 and when alerts will be scheduled to trigger see the figure and...

Страница 11: ...01 0544 01 22 folder created when you installed Click Supervisor under Wavetronix ClickHome Drivers 513 User You can also select Save to Device to save your settings to your Click 513 Note If you do n...

Отзывы: