LINE
ACCESS
LEVEL
FUNCTION
SETTING RANGE
OR DISPLAY
FACTORY
SETTING
Heating circuit 2
1010
U
Comfort setpoint
Reduced setpoint…
Comfort setpoint maximum
20°C
1012
U
Reduced setpoint
Frost protection setpoint…
Comfort setpoint
19.0°C
1014
U
Frost protection setpoint
4°C… Reduced setpoint
8.0°C
1016
S
Comfort setpoint maximum
Comfort temp... 35 °C
28.0°C
1020
I
Heating curve slope
0.1…4
0.5
1021
I
Off-set of the heating curve
-4.5…4.5°C
0°C
1030
I
Summer / winter heating limits
8...30 °C
18°C
1040
I
Flow temp setpoint min
8…70°C
17°C
1041
I
Flow temp setpoint max
8…70°C
55°C
1050
S
Room influence
1...100%
50%
1060
S
Room temperature limitation
0.5…4°C
0.5°C
As soon as the room temperature = [Setpoint line 1010 (ex. 20°C) + Room temperature
limitation setpoint line 1060 (ex. 0,5 °C)] > 20,5 °C => The heat pump is stopped.
It restarts when the room temperature falls below the setpoint (in the example, Room
temperature < 20,0 °C).
1080
S
Quick setback
Off
Down to reduced setpoint
Down to frost prot setpoint
Off
1090
S
Optimum start control max
0…360 min
180 min
1091
S
Optimum stop control max
0…360 min
30 min
1100
S
Reduced setpoint increase start
---, -30…10°C
---°C
1101
S
Reduced setpoint increase end
---, -30…10°C
-5°C
1130
S
Mixer valve boost
0…50°C
0°C
1134
S
Actuator running time
30…873sec
240sec
1150
I
Floor curing function
Off
- Off: Early interruption of the current programme, programme inactive.
- Operational heating.
- Heating ready for occupation.
- Operational h ready heating.
- Ready h operational heating.
- Manual: Manual mode enables you to programme your own concrete slab drying time.
The function ends automatically after 25 days
1151
I
Floor curing setpoint manually
(if line 1150 = manual)
0…95°C
25°C
This function enables you to set the custom concrete slab drying temperature. This
temperature remains fixed.
The concrete slab-drying program stops automatically after running for 25 days.
1156
I
Floor curing day current
0... 32
1157
I
Floor curing day completed
0... 32
0
1200
S
Operating mode changeover
None, Protection mode,
Reduced, Comfort,
Automatic
Reduced
Domestic hot water
1600
U
Operating mode
Off, On, Eco
On
1610
U
Nominal setpoint
Reduced setpoint (line
1612)…65 °C
55°C
The backup electrical system is required to reach this level.
1612
U
Reduced setting
8 °C...Nominal setting
(line 1610)
40°C