- (CS01 - 64) -
Control system
- (CS01 - 64) -
C
O
N
T
R
O
L
SY
S
T
E
M
C
O
N
T
R
O
L
SY
S
T
E
M
Diagnostics consumers functions
z
Various setpoints and actual values, relay switch
status and timing status data can be displayed for
purposes of diagnosis.
Outside Temperatures
LINE
FUNCTION
8700
Outside temp
8701
Outside temp min
8702
Outside temp max
8703
Outside temp attenuated
8704
Outside temp composite
The current, minimum, maximum, attenuated and
composite outdoor temperatures are displayed.
Heating Circuits
LINE
FUNCTION
8730 and 8760 heating circuit pump 1 and 2
8731 and 8761
Heating circuit mix valve 1 open
8732 and 8762
Heating circuit mix valve 1 closed
8740 and 8770 Room temp 1 and 2
8743 and 8773 Flow temp 1 and 2
The display "Off" means that the associated
components are currently disconnected.
The display "On" means that the associated
components are currently switched on.
Cooling Circuit
LINE
FUNCTION
8756
Flow temperature cooling 1
8757
Flow temperature setpoint cooling 1
The actual value of the cooling mode are displayed.
The cooling mode room setpoint is displayed on
programming line 8741.