- (OU01 - 07) -
Outdoor unit / 3 phase
O
U
T
D
O
O
R U
N
IT
WO
K1
1
2
-1
6
0
L
C
T
A
O
U
T
D
O
O
R U
N
IT
WO
K1
1
2
-1
6
0
L
C
T
A
PRODUCT INFORMATION
2-41
Product information according to Commission Delegated Regulation (EU) 813/2013
Product information is based on the average climate condition.
Model
Hydraulic unit
WSYK160DG9
WSHG140DG *1
WGYK160DG9
WGHG140DG *1
WSYK160DG9
WSHG140DG *1
WGYK160DG9
WGHG140DG *1
Outdoor unit
WOYK112LCTA
WOHK112LCTA
WOYK140LCTA
WOHK140LCTA
Air-to-water heat pump
Yes
Water-to-water heat pump
No
Brine-to-water heat pump
No
Low-temperature heat pump
No
Equipped with a supplementary heater
Yes
Heat pump combination heater
Yes
Temperature application
°C
55
35
55
35
55
35
55
35
Rated heat output *2
P
rated
kW
9
11
9
11
11
13
11
13
Seasonal space heating energy efficiency
ƞ
s
%
112
154
112
154
117
150
117
150
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature T
j
T
j
= –7 °C
Pdh
kW
8.2
10.0
8.2
10.0
10.0
11.1
10.0
11.1
T
j
= +2 °C
Pdh
kW
5.0
6.1
5.0
6.1
6.1
6.7
6.1
6.7
T
j
= +7 °C
Pdh
kW
5.9
6.2
5.9
6.2
5.9
6.2
5.9
6.2
T
j
= +12 °C
Pdh
kW
7.0
7.4
7.0
7.4
7.1
7.3
7.1
7.3
T
j
= bivalent temperature
Pdh
kW
8.2
10.0
8.2
10.0
10.0
11.1
10.0
11.1
T
j
= operation limit temperature
Pdh
kW
8.1
9.9
8.1
9.9
9.3
10.8
9.3
10.8
T
j
= –15 °C (if TOL < –20 °C)
Pdh
kW
—
—
—
—
—
—
—
—
Bivalent temperature
T
biv
°C
-7
-7
-7
-7
-7
-7
-7
-7
Cycling interval capacity for heating
P
cych
kW
Not applicable
Degradation co-efficient *3
Cdh
—
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature T
j
T
j
= –7 °C
COP
d
—
1.91
2.65
1.91
2.65
1.95
2.53
1.95
2.53
T
j
= +2 °C
COP
d
—
2.74
3.74
2.74
3.74
2.85
3.65
2.85
3.65
T
j
= +7 °C
COP
d
—
3.94
5.47
3.94
5.47
4.07
5.37
4.07
5.37
T
j
= +12 °C
COP
d
—
5.16
7.08
5.16
7.08
5.39
7.03
5.39
7.03
T
j
= bivalent temperature
COP
d
—
1.91
2.65
1.91
2.65
1.95
2.53
1.95
2.53
T
j
= operation limit temperature
COP
d
—
1.59
2.28
1.59
2.28
1.61
2.39
1.61
2.39
T
j
= –15 °C (if TOL < –20 °C)
COP
d
—
—
—
—
—
—
—
—
—
Operation limit temperature
TOL
°C
-10
-10
-10
-10
-10
-10
-10
-10
Cycling interval efficiency
COP
cyc
—
Not applicable
Heating water operating limit temperature
WTOL
°C
60
60
60
60
60
60
60
60
Power consumption in modes other than active mode
Off mode
P
OFF
kW
0.014
0.014
0.014
0.014
0.014
0.014
0.014
0.014
Thermostat-off mode
P
TO
kW
0.032
0.044
0.032
0.044
0.029
0.066
0.029
0.066
Standby mode
P
SB
kW
0.017
0.017
0.017
0.017
0.017
0.017
0.017
0.017
Crankcase heater mode
P
CK
kW
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
Supplementary heater
Rated heat output *2
P
sup
kW
1.2
1.4
1.2
1.4
2.0
1.7
2.0
1.7
Type of energy input
Electric
Other items
Capacity control
Variable
Sound power level
Indoor unit
L
WA
dB
46
46
46
46
46
46
46
46
Outdoor unit
L
WA
dB
69
68
69
68
70
68
70
68
Emissions of nitrogen oxides
NO
x
mg/kWh
Not applicable
Rated air flow rate
Outdoor unit
—
m³/h
6200
6200
6200
6200
6200
6200
6200
6200
Declared load profile
—
—
L
L
—
—
L
L
Daily electricity consumption
Q
elec
kWh
—
—
5.300
5.300
—
—
5.300
5.300
Water heating energy efficiency
η
wh
%
—
—
88
88
—
—
88
88
Daily fuel consumption
Q
fuel
kWh
Not applicable
Contact details
FUJITSU GENERAL (EURO) GmbH
Werftstraße 20, D-40549 Düsseldorf, F. R. Germany
*1: Optional electrical back up heater consumption is taken into account in the performance calculation.
*2: For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
P
designh
, and the rated heat output of a supplementary heater P
sup
is equal to the supplementary capacity for heating sup (T
j
).
*3: If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.