Heating circuit 1 & 2 functions
z
Operating Mode
For heating circuits there are several functions
available which can be individually adjusted for
each heating circuit.
The programming lines for the 2nd heating circuit
are displayed only if the extension module has
been connected to the controller.
Operation of heating circuits 1 and 2 is directly
controlled via the operating mode key.
Setpoint Values
LINE
FUNCTION
HC1
HC2
710
1010
Comfort setpoint
712
1012
Reduced setpoint
714
1014
Frost protection setpoint
716
1016
Maximum comfort setpoint
Room temperature:
Room temperature can be set according to different
setpoint values. Depending on the selected mode,
these setpoints are activated and provide different
temperature levels in the rooms.
The ranges of configurable setpoints are defined
by their interdependencies, as shown in the graph
below.
Comfort setpoint
Comfort setpoint max
Reduced setpoint
Frost prot3 setpoint
Frost protection:
The protection mode automatically prevents an
excessively sharp drop in room temperature.
In this case the control adopts the frost protection
room setpoint.
Heating Curve
LINE
FUNCTION
HC1
HC2
720
1020
Heating curve slope
721
1021
Heating curve displacement