- (CS01 - 20) -
Control system
- (CS01 - 20) -
C
O
N
T
R
O
L
SY
S
T
E
M
C
O
N
T
R
O
L
SY
S
T
E
M
LINE
ACCESS
LEVEL
FUNCTION
SETTING RANGE
OR DISPLAY
FACTORY
SETTING
8743
U
Flow temperature 1
0... 140 °C
---
Flow temperature setpoint 1
---
8749
I
Room thermostat 1
No demand, Demand
No demand
8756
U
Cooling flow temperature 1
0... 140 °C
---
Cooling flow temperature setpoint 1
---
8820
I
DHW pump
Off, On
Off
8821
I
Electric immersion heater DHW
Off, On
Off
8830
U
DHW temperature
0... 140 °C
---
DHW temp setpoint
50°C
8832
I
DHW temp 2
0... 140 °C
---
8840
S
Hours run DHW pump
0…2730h
---
8841
S
Start counter DHW pump
0... 199999
---
8842
S
Hours run electric DHW
0…2730h
---
8843
S
Start counter electric DHW
0…65535
---
8950
I
Common flow temperature
0... 140 °C
---
Common flow temperature setpoint
---
8957
I
Common flow setpoint refrig
0... 140 °C
---
9005
I
Water pressure 1
-100... 500 bar
---
9006
I
Water pressure 2
-100... 500 bar
---
9009
I
Water pressure 3
-100... 500 bar
---
9010
I
Measurement room temp 1
0...50 °C
---
9011
I
Measurement room temp 2
0...50 °C
---
9031
I
Relay output QX1
Off, On
On
9032
I
Relay output QX2
Off, On
On
9033
I
Relay output QX3
Off, On
On
9034
I
Relay output QX4
Off, On
Off
9035
I
Relay output QX5
Off, On
Off
Description of abbreviations :
HC = Heating circuit
OT = Outside temperature
HP = Heat pump
DHW = Domestic hot water
BXx, EXx, QXx, DOx, UXx, Hx = Terminal number