- (CS01 - 12) -
Control system
- (CS01 - 12) -
C
O
N
T
R
O
L
SY
S
T
E
M
C
O
N
T
R
O
L
SY
S
T
E
M
LINE
ACCESS
LEVEL
FUNCTION
SETTING RANGE
OR DISPLAY
FACTORY
SETTING
Time program 4 / DHW
560
U
Pre-selection (Day / Week)
Mon-Sun, Mon-Fri, Sat-Sun,
Monday, Tuesday, …
Mon-Sun
561
U
1
st
phase on (start)
00:00…--:--
00:00
562
U
1
st
phase off (end)
00:00…--:--
05:00
563
U
2
nd
phase on (start)
00:00…--:--
14:30
564
U
2
nd
phase off (end)
00:00…--:--
17:00
565
U
3
rd
phase on (start)
00:00…--:--
--:--
566
U
3
rd
phase off (end)
00:00…--:--
--:--
576
U
Default values, Circuit 2
No, Yes
No
Yes + OK: The default values memorised in the regulator replace and cancel the
customised heating programs.
Your customised settings are therefore lost.
Holidays heating circuit 1
641
U
Preselection
Period 1…8
Period 1
642
U
Period start (Day / Month)
01.01…31.12
--:--
643
U
Period end (Day / Month)
01.01…31.12
--:--
648
U
Operating level
Frost protection,
Reduced
Frost
protection
Holidays heating circuit 2
651
U
Preselection
Period 1…8
Period 1
652
U
Period start (Day / Month)
--:--, 01.01…31.12
--:--
653
U
Period end (Day / Month)
--:--, 01.01…31.12
--:--
658
U
Operating level
Frost protection,
Reduced
Frost
protection
Heating circuit 1
710
U
Comfort setpoint
Reduced setpoint…
Comfort setpoint maximum
20°C
712
U
Reduced setpoint
Frost protection setpoint…
Comfort setpoint
19°C
714
U
Frost protection setpoint
4 °C… Reduced setpoint
8°C
716
S
Comfort setpoint maximum
20…35°C
28°C
720
I
Heating curve slope
0.1... 4
0.5
721
I
Off-set of the heating curve
-4.5…4.5°C
0°C
730
I
Summer / winter heating limits
8…30°C
18°C
When the average of the outside temperatures over the past 24 hours reaches 18°C, the
regulator switches off the heating (as an economy measure). During summer mode, the
display shows "Eco". This function is only active in automatic mode.
740
I
Flow temp setpoint min
8 °C... Flow temp
setpoint max
17°C
(with dynamic radiator, adjust from 30 to 35°C)
741
I
Flow temp setpoint max
Flow temp setpoint min...
70 °C
55°C
Floor heating system = 50 °C / Radiators = 65 °C.
Important Note : Maximum temperature limitation is not a safety function as required by
ground heating.
750
S
Room influence
1...100%
50%