background image

1

Air Conditioning Unit 

Installation & Instruction Manual 

Integrated Air Conditioning

Содержание Air8

Страница 1: ...1 Air Conditioning Unit Installation Instruction Manual Integrated Air Conditioning ...

Страница 2: ...providing outstanding perfor mance and a pleasant environment for the warmest of days Cold air is circulated evenly throughout the interior of your living space thanks to a ducting system which minimizes hot spots and provides an even temperature through out Additionally the ducted air distribution minimizes noise while delivering maximum cooling efficiency To maintain our pre mium standard in eve...

Страница 3: ...ON DIMENSIONS 2 5 INSTALLATION INSTRUCTION 3 5 1 Installation location 3 5 2 How to install the AC unit 4 5 3 How to build the air duct 5 5 3 1 Cold air distribution 5 5 3 2 Circulated air return 5 5 4 How to install the wall pad 5 5 5 Power supply connection and wall pad to control board connection 6 6 OPERATING INSTRUCTION 6 6 1 Wall Pad 7 6 2 Alarm Code 8 ...

Страница 4: ...y operation send the unit back to the distributor or to Bergstrom with a de tailed description of the fault Ensure that the wires for wall pad loads and the power supply are separated and far enough from each other without crossing or intertwining Ensure the unit operating properly the air inlet outlet must not be obstructed by any obstacle The openings under the floor of the vehicle must be kept ...

Страница 5: ...rating current 9 A Max tilt of unit in operation 5 Protection class IP 54 Tested under the following conditions Cooling A R I Standard Conditioning 80º F DB 67º F WB Indoor 95º F DB Outdoor at 115VAC 4 INSTALLATION DIMENSIONS Sensors information A built in air sensor to monitor the circulated air temperature An Anti freeze air sensor avoids evaporator coil from freezing during operation A discharg...

Страница 6: ... may need to be fitted with additional gaskets if the system is attached to a floor with grooves for instance The room air which has been cooled is drawn in again from the vehicle interior by the unit via openings with a total area not less than 50 sq in If possible position the unit so that the frame of the vehicle is between the air inlet AI and the air outlet AO Insert the installation template...

Страница 7: ...ation drain WD from above Seal connector 4 for condensation drain all round from below using body sealant NOTE When installing the unit please ensure that the connector 4 of the condensation drain has been located in the recess in the floor of the vehicle If not the water will permeate into the interior In order to provide perfect air circulation the apertures in the base of the equipment and the ...

Страница 8: ...city In order to avoid condensation do not route the cold air ducts close by inflowing outside air or behind the refrigerator 5 3 2 Circulated Air Return The circulated air is drawn in again by the unit either via an additional rectangular air grille or via several small openings e g in the stowage box wall with a total area of at least 50 sq in NOTE The flue from the vehicle interior to the AC un...

Страница 9: ...s must be long enough for the unit to be pulled out of the false floor with the cables attached All cables must be secured with clamps An insulating device for providing all pole insulation from the mains with contact clearance of at least 0 14 inch must be provided at the vehicle end for carrying out maintenance and repair work 6 OPERATING INSTRUCTION Must be carefully read the operating instruct...

Страница 10: ...tton together for 6 seconds into timer setting after buzzer rangs twice and is flashing then loosen the buttons this procedure will pass the clock date setting 2 If the timer is disable the symbols zone will display 3 Press button to adjust date setting from Sun day to Saturday meanwhile keeps flashing 4 Press or button to adjust the clock meanwhile keeps flashing If timer hasn t been settled earl...

Страница 11: ...ailure E2 Coil sensor failure E5 Compressor overload E7 High pressure sensor trigger E15 Wall pad and control board communication failure E16 Coil frozen detected E22 Discharge temperature sensor failure E23 High discharge temperature Ducted Quiet Efficient ...

Страница 12: ...9 Elwell Corporation Tel 360 608 0916 Email info elwellcorp com 680 C South 28th St Washougal WA 98671 ...

Отзывы: