12 Month Servicing Guide 

• Servicing of the Countertop needs to take place every 12 months. Operational, 

  maintenance, and replacement requirements are essential for the water-treatment 

  device to perform as represented 

• During the 12 month service it is recommended you de-scale the hot tank in order

  to remove any calcium build up inside the tank, just like you would a kettle. Please 

  use the Waterlogic Countertop De-scaling Kit. If you do de-scale the machine, 

  please do so prior this service procedure 

• The filter and UV lamp must be replaced at this service

• Some units may have screws holding the lid on that will need to be unscrewed  

  before the lid can be removed. This will be model dependant. Screws will need 

  to be put back when the lid is replaced

• Servicing must be performed by an adult

WHAT YOU ARE GOING TO NEED WHEN SERVICING  

THE WATERLOGIC COUNTERTOP                      

Countertop Pure Kit, 

which includes a sediment 

filter, a carbon filter and 

a UV lamp 

Please make sure you use only 

original Waterlogic replacement 

parts. If you are not sure which 

replacement parts to use, please 

consult with your local Waterlogic 

retailer or distributor

Phillips / cross head 

screwdriver 

A container that can 

hold 5 litres

Latex rubber gloves

Recommended

Содержание Countertop Pure K-FU-00S20-00C1L-13-0-XXX

Страница 1: ...ervice Guide Waterlogic Countertop Pure Kit K FU 00S20 00C1L 13 0 XXX includes sediment filters FT 0003 L00 XXX carbon filter FT 0006 L00 XXX UV lamp CT 2090 C Only for use with Waterlogic Countertop...

Страница 2: ...for purchasing the Waterlogic Countertop Pure Kit Please read this manual before servicing the Countertop machine Index Declarations 3 Box contents 4 12 month servicing guide 6 Product disposal 16 Per...

Страница 3: ...ons such as staff kitchen areas in shops offices and other working environments farm houses and by clients in hotels motels and other residential type environments bed and breakfast type environments...

Страница 4: ...4 IN THE COUNTERTOP PURE KIT BOX YOU WILL FIND 1 Waterlogic sediment filter 2 Waterlogic carbon block filter CBC 3 Waterlogic Firewall UV bulb Box Contents...

Страница 5: ...des a 1 micron carbon block filter with cyst lead reduction capabilities and a 13 Watt UV C lamp that requires periodoc replacement annually in most cases Please ensure you purchase only original Wate...

Страница 6: ...nd UV lamp must be replaced at this service Some units may have screws holding the lid on that will need to be unscrewed before the lid can be removed This will be model dependant Screws will need to...

Страница 7: ...point 1 3 Select the cold water icon until it lights up Whilst the cold water icon is lit select and hold the central dispense button when the water stops flowing release the button and continue to s...

Страница 8: ...ne from under wall units to allow access This is why it is important you fit an extra 15 30cm of the flexible tubing from the water supply when installing the unit Please take care not to dislodge the...

Страница 9: ...block filter assembly into its cradle with the filter loop on the left see picture F which enables the filter shape to perfectly fit the cradle profile 2 4 Push the filter firmly into place until the...

Страница 10: ...tion see picture H H I 3 2 Remove the filter by pulling straight upwards on the filter loop see picture I 3 3 Insert the new sediment filter assembly into its cradle with the filter loop on the left s...

Страница 11: ...ct the UV lamp connector by pressing in the clip on the side of the connector step 1 and pulling the connector towards the front of the machine step 2 see picture N M L UV protective cover UV protecti...

Страница 12: ...to avoid breaking it ensure that it is fully vertical when you insert it and do not use excessive force 4 5 Insert the connector on the new UV lamp into the UV connector in the machine see picture Q P...

Страница 13: ...making sure the two fixing lugs at the front are lined up with the grooves step 1 and then pulling the cover firmly towards yourself until it clicks into place step 2 see picture S If your machine ha...

Страница 14: ...ng water Continue to hold the dispense button until 8 litres of ambient water has passed through the machine Once 8 litres has passed through release the dispense button and the water flow will stop T...

Страница 15: ...be up to operating temperature after 8 10 minutes and the cold water will take between 60 90 minutes to cool 6 2 The water should now be taste tested if there is any hint of taste in the water then f...

Страница 16: ...ducts are covered by the Waste Electrical and Electronic WEEE directive 2002 96 EC The symbol shown above denotes that the product should not be disposed of with general household waste Hand it in at...

Страница 17: ...reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 NSF ANSI 53 NSF ANSI 55 Class A and NSFANSI P231 While testing was condu...

Страница 18: ...Jinling Road Jinling Industrial Zone Chengyang District Qingdao 266111 Shandong P R CHINA TEL 86 532 87909132 Tested using flow rate 0 5 GPM pressure 60 psi pH 7 5 0 5 temp 20 1 0 C Operating Specific...

Страница 19: ...erformance may vary based on local water conditions seconds WARRANTY Waterlogic International Waterlogic warrants that the products delivered will be free from any defects in workmanship or materials...

Страница 20: ...pe you love drinking good water as much as we do Please let us know your thoughts by email to goodwater waterlogic com To speak to a Water Expert please refer to your Guarantee and After sales service...

Отзывы: