Page 2: ...ng and storage 16 4 1 Delivery check 16 4 2 Packaging 16 4 3 Storage 16 5 Technical data 17 6 Operation of the device 17 7 Installation 18 7 1 Information for the installer 18 7 2 Installation of the water filter system 19 8 Possible malfunctions 23 Bartscher GmbH Franz Kleine Str 28 D 33154 Salzkotten phone 49 0 5258 971 0 Germany fax 49 0 5258 971 120 GB UK ...

Page 3: ... this instruction manual Manufacturer is not liable for any damages or faults caused by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts Do not use any accessory or spare parts that have not been recommended by the manufacturer These can be dangerous for the user or lead to damages of the device or personal injury ...

Page 4: ...tres 14 days Replace the filter Do not disassemble the water filter system during its use Do not open the water filter system because this will void the warranty 3 Intended use Safety of the device s operation is guaranteed only when using it according to its intended purpose in compliance with the data included in the operating instructions The water filter system for coffee machines is designed ...

Page 5: ... a repair center The outer and inner packing material should be removed completely from the device before installation NOTE Drain water from the system before shipment to avoid damaging the packaging caused by water leakage NOTE If you liked to dispose the packing consider the regulations applicable in your country Supply re usable packing materials to the recycling Please inspect the device upon ...

Page 6: ...l Plastic Capacity For 10 CH carbonate hardness 1600 litres Max system pressure 1 5 6 bar Water temperature 5 C 30 C Connection thread 1 2 Dimensions W 200 x D 140 x H 320 mm Weight 2 2 kg Subject to technical modifications 6 Operation of the device The water filter system was designed to reduce the carbonate hardness CH in the drinking water which produces scale deposits that may damage the devic...

Page 7: ...heat and open flame Do not expose the device to the direct sunlight Protect the water filter system against mechanical damages Install the shut off valve upstream of the water filter system Install the drain valve on the drain hose downstream of the water filter system If the water pressure in the water supply installation exceeds 6 bar install the pressure regulator upstream of the water filter s...

Page 8: ...ing bracket for wall mounting It can be mounted horizontally or vertically Install the mounting bracket in the desired place The mounting bracket is a fixed component of the device and the water filter system is always replaced along with the mounting bracket 4 Install the water filter system in compliance with the local standards for drinking water installation 5 Perform the test in order to dete...

Page 9: ...e hose which will connect the water outlet OUT with the terminal unit 5 Open the water supply and connect the terminal unit to the power supply 6 Check the system for leakages Replacement of the water filter system 1 The water filter system needs to be replaced after reaching a specified volume depending on the carbonate hardness during the period defined by the manufacturer but not later than wit...

Page 10: ...the appropriate container e g bucket o Open the water supply to the filter and flush the system until the water starts flowing evenly without air bubbles o Close the shut off valve Connect the hose to the water outlet OUT and connect the other end of the hose to the terminal unit b Replacement of the filter with quick fit connectors see illustrations below 1 filter ready for replacement 2 prize th...

Page 11: ... replace the old one During the installation observe the mounting dimensions and hose bending radius 7 After the filter replacement close the drain valve 8 Open the shut off valve on the water inlet and connect the terminal unit to the power supply 9 Check the system for leakages Table of volumes Carbonate hardness CH quoted in dH German degrees Volume l min Carbonate hardness CH quoted in dH Germ...

Page 12: ...tact a local waste management agency 8 Possible malfunctions Problem Cause Solution No water flow Closed water inlet Open the shut off valve on the water inlet Pressure too low Too low pressure in the installation Check the pressure in the water supply network Clogged hoses or filter Check the water filter system water inlet and drain hoses replace if necessary Air in the installation Check the in...

Page 13: ...gher than 8 dH Filter capacity exceeded Replace the filter A different hardness than a carbonate hardness has been measured Check the carbonate hardness Water from the water installation does not meet hygienic requirements presence of iron manganese or other compounds in the water supply network which contaminate or damage the resin Check the quality of water in the water supply network replace th...