GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
• This appliance is for use with potable drinking water only. Never use this appliance
with unknown or unsafe sources.
• Flush the hot tank, cold tank and filters as instructed.
• Replace filter cartridge when rated capacity is reached, or every 12 months, or
when flow becomes to slow.
• Replace UV lamps every 12 months, or when the UV intensity is lower than required.
• Install in compliance with state and local laws and regulations.
Manufactured by Qingdao Waterlogic Manufacturing Co., Ltd
No 10 Jinling Road, Jinling Industrial Zone, Chengyang District, Qingdao, 266111,
Shandong, P.R. CHINA TEL: +86-532-87909132
Tested using flow rate=0.5 GPM; pressure=60 psi; pH=7.5 ± 0.5; temp.=20 ± 1.0 °C.
Operating Specifications
Filter Capacity
2,500 Gallons / 9,464 Liters
Lead Capacity
1,250 Gallons / 4,732 Liters
Maximun Flow Rate
0.34 GPM / 1.3 LPM
Feed Water Temperature
2 °C / 35 °F - 32 °C / 90 °F
Operating Temperature
5 °C / 41 °F - 30 °C / 86 °F
Working Pressure
0.26Mpa / 37.7Psi - 0.414Mpa / 60 Psi
Electrical Requirements
EU: 220-240V 50Hz / maximum 3.0 amps;
USA: 120V 60Hz / maximum 6.2 amps
UV Performance Data Table
Parameter
Log Reduction Average
Bacteria (R.terrogema)
7.4 Log
Virus (MS2)*
3.16 Log
Note: 2 Log reduction of MS2 is equivalent to 4 Log reduction of Poliovirus or Rotavirus