Product Disposal
Performance Data Sheet
MODEL NAME: F-FWCU1-M-HCA-TT-XX-YY2 WATERLOGIC
COUNTERTOP WATER PURIFIER WITH CYST/LEAD REMOVAL
FILTER FT-0006-L00-YYY AND SEDIMENT REMOVAL FILTER
FT-0003-L00-YYY
XX: COLOR CODE, -YY2: CUSTOMER CODE
IMPORTANT NOTICE
This system, when used with FT-0006-L00-WLT 1 micron CBC cyst
and reduction filter, has been tested according to NSF/ANSI 42, NSF/
ANSI 53, NSF/ANSI 55 Class A and NSF/ANSI P231 for the reduction
of the substances listed below.
Tested using flow rate=0.5 GPM; pressure=60 psi; pH=7.5 ± 0.5; temp.=20 ± 1.0 °C.
The concentration of the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42, NSF/ANSI 53, NSF/ANSI 55 Class A and NSFANSI P231.
While testing was conducted under standard laboratory conditions, actual performance
may vary.
Filter Performance Data Table
Parameter
Minumum
% reduction
requirement /
Max effluent
concentration
Average
Influent
Challenge
Effluent
Average
Effluent
Maximum
Percent
Reduction
Average
Percent
Reduction
Minimum
Chlorine
>=50% reduction
1.90 ppm
0.02 mg/L 0.02 mg/L
98.9%
98.9%
Cyst
>=99.95%
reduction
120,000
oocyst/L
38
oocyst/L
< 50
oocyst/L
99.99%
99.97%
Lead
(Low pH = 6.5)
< 10 ug/L
144 ug/L
0.49 ug/L 1.60 ug/L
99.7%
98.9%
Lead
(High pH =
8.5)
< 10 ug/L
140 ug/L
1.47 ug/L
7.50 ug/L
98.9%
94.6%
Particulate
Class I (>=0.5
um to <1 um)
>=85% reduction
>/=10,000
particles/ml
288
particles/ml
704
particles/ml
97.9%
94.9%