Waterlogic® Countertop Service Guide - Version 1, May 2015
19
Tested using flow rate=0.5 GPM; pressure=60 psi; pH=7.5 ± 0.5; temp.=20 ± 1.0 °C.
SPECIAL NOTICES
• The contaminants or other substances removed or reduced by this water treatment
system are not necessarily in your water.
• Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
• System certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.
• This Class A system conforms to NSF/ANSI 55 for the disinfection of microbiologically
contaminated water that meets all other public health standards. The system is not
intended to convert wastewater or raw sewage to drinking water. This system is
intended to be installed on visually clear water.
NSF/ANSI 55 defines wastewater to include human and/or animal body waste, toilet
paper, and any other material Intended to be deposited in a receptacle designed
to receive urine and/or feces (blackwaste); and other waste materials deposited in
plumbing fixtures (greywaste).
• Performance may vary based on local water conditions seconds.
WARRANTY
Waterlogic International (Waterlogic) warrants that the products delivered will be free
from any defects in workmanship or materials. Further, the warranty provided here in
applies, only when used within the products specifications and service life, from the date
of installation, beyond which time or use Waterlogic is absolved of any and all liability for
any use of the product. In the event of defect or non-conformity, buyer shall promptly
notify Waterlogic in writing, supplying proof of purchase dates, installation dates, and will
protect and retain the products for investigation, or Waterlogic is absolved of any and all
liability for any use of the product. There are no other warranties, either merchantability
or fitness, either expressed or implied.
FOR IOWA ONLY
The Manufacturer’s PDS shall be given to the buyer by the seller and shall be signed
and dated by the buyer and the seller prior to the consummation of the sales of the
water treatment system and retained on file by the seller for a minimum of two years.
Seller _________________________ Date _______________________
Buyer __________________________ Date______________________
Operating Specifications
Filter Capacity
2,500 Gallons / 9,464 Liters
Lead Capacity
1,250 Gallons / 4,732 Liters
Maximun Flow Rate
0.34 GPM / 1.3 LPM
Feed Water Temperature
2 °C / 35 °F - 32 °C / 90 °F
Operating Temperature
5 °C / 41 °F - 30 °C / 86 °F
Working Pressure
0.26Mpa / 37.7Psi - 0.414Mpa / 60 Psi
Electrical Requirements
EU: 220-240V 50Hz / maximum 3.0 amps;
USA: 120V 60Hz / maximum 6.2 amps
UV Performance Data Table
Parameter
Log Reduction Average
Bacteria (R.terrogema)
7.4 Log
Virus (MS2)*
3.16 Log
Note: 2 Log reduction of MS2 is equivalent to 4 Log reduction of Poliovirus or Rotavirus