Installation In  

7 Easy Steps

1.  Remove the TWIST

II

CLEAN 

from its box. Check to make 

sure the box also contains a 

small dispenser of Teflon tape 

and two slip/threaded adapters 

for use if needed.

2.  Be sure the clear bowl is 

securely tightened (hand tighten 

only). The unit is shipped with 

the bowl loose. Lift the red 

safety latch and rotate the top 

handle a few times to make 

sure it will rotate 

1/4

 clockwise 

turn.

3.  Prepare the piping manifold 

to install TWIST

II

CLEAN. 

Select the best fittings for 

your installation, using slip 

or threaded fittings as desired. 

Notice the direction of water 

flow through the unit -- a flow 

direction arrow is molded into 

the side of the unit. (Fig A).

4. Use proper PVC solvents and 

follow gluing instructions on solvent container. Do not 

spill solvent on any part of the TWIST

II

CLEAN unit.

5.  Mounting eyelets provide for a more stable installation (Fig 

B). Stabilizer bolts are recommended for long term stability 

of your TWIST

II

CLEAN. Use ⅜" Hex Lag Screws plus 

washers and PVC pipe to connect to a secure surface. 

These parts are NOT supplied with your TWIST

II

CLEAN. 

6.  Once installed, test by turning water supply on slowly, 

allowing water to feed through the unit. Check for 

leaks. After lifting the safety latch, twist the top handle 

with a ¼ clockwise turn to re-direct the flow for cleaning. 

This should lift the screen element inside the bowl and 

release flush water through the Purge Exit at the bottom of 

the unit. Twist the handle back to its “run” position, lower 

the safety latch and check for leaks.

7. Attach a flush drain hose (if necessary) to direct the 

purged particle matter and excess water to a drain or other 

desired area for discharge (Fig C).

A.  Select a good filter location:

Install on the pressure (outlet) side of any pumps and 

pressure tanks

In a vertical position with Purge Exit pointing down

Away from extreme weather conditions to protect 

from freezing

At least 12 inches away from walls or obstructions, 

so top handle can be twisted

Allow enough clearance beneath the unit to: 

 

 

(a)    attach a purge drain hose to the Purge Exit 

(recommended) 

 

 

(b)    remove the clear bowl assembly, to allow 

replacement of element as needed

B.    As a sunny outdoor installation might lead to algae 

growth inside the clear bowl and affect the operation 

of your TWIST

II

CLEAN, an optional Sun Shield is 

available.

Maximum Flow Ranges: 

•  T2C-075 ¾" Inlet/Outlet: 0 to 25 US gpm (0 to 5.7 m³/hr)

•  T2C-100 1" Inlet/Outlet: 0 to 39 US gpm (0 to 8.9 m³/hr)

•  T2C-150 1 

1/2"

 Inlet/Outlet: 0 to 78 US gpm (0 to 17.7 m³/hr)

Maximum Pressure:

•  100 psi at 73˚F (6.9 bar at 38˚C)

Temperature Range:

•  32˚F - 120˚F (0˚C - 49˚C)

Mesh Sizes:

•  30 Mesh (600 Micron) Element (Brown)

•  60 Mesh (250 Micron) Element (White)

•  100 Mesh (150 Micron) Element (Gray)

•  140 Mesh (105 Micron) Element (Black)

•  200 Mesh (74 Micron) Element (Blue)

Pre-Installation Checklist

Top Handle

Red Safety Latch

Inlet

Outlet

Flow Direction Arrow

Mounting 

Eyelets

Clear Bowl

Filter Element

Purge Exit

LS-866B (Rev. 5/13)

Inlet/Outlet to Purge Port

Total Length

TWIST

II

CLEAN

Installation Instructions for:   3/4-inch Model T2C-075 

1-inch Model T2C-100 

1 1/2-inch Model T2C-150

Installation and 

Operation Guide

Width

Dimensions

Total

Fig A

Fig B

Fig C

Optional Accessories

Sun Shield For Outdoor Installations

Black neoprene woven cover, slips over bowl  

to prevent growth of algae and other organics.

Purge Exit

Hose

  Model Size 

Sun Shield Part Number

  T2C-075 (¾") 

131355

  T2C-100 (1")
  T2C-150 (1-½") 

132240

SUN SHIELD

Summary of Contents for TwistIIClean

Page 1: ... and excess water to a drain or other desired area for discharge Fig C A Select a good filter location Install on the pressure outlet side of any pumps and pressure tanks In a vertical position with Purge Exit pointing down Away from extreme weather conditions to protect from freezing At least 12 inches away from walls or obstructions so top handle can be twisted Allow enough clearance beneath the...

Page 2: ...l if the filter is to be installed using any solvent welding This will prevent solvent damage to the clear bowl 7 This filter is designed for use with water only Other chemicals or components can damage the filter components Evaluate all chemicals for proper usage with the filter 8 Protect unit from freezing as you would with any other water supply lines 9 Follow all local and state codes laws and...

Page 3: ...para el filtro Instale en el lado de presión salida de cualesquiera bombas y tanques de presión En posición vertical con la Salida de purga en dirección hacia abajo Alejado de condiciones extremas de clima para protegerlo de la congelación Alejado cuando menos 30 cm 12 pulg de paredes u obstrucciones de manera tal que la manija superior pueda ser girada Permita el suficiente espacio bajo la unidad...

Page 4: ...os no requieren sellador de roscas 6 Desmonte el tazón transparente si el filtro se va a instalar mediante el uso de pegamento disolvente Esto impedirá que el disolvente dañe el tazón transparente 7 Este filtro está diseñado para usarse con agua únicamente Otros químicos o componentes pueden dañar a los componentes del filtro Evalúe todos los químicos con respecto al uso correcto con el filtro 8 I...

Reviews: