296 Appendix
WAGO-ETHERNET-Zubehör 852
852-1305 8/4-Port 100BASE-T/1000BASE-SX/LX
Manual
1.1.0
Table 161: MODBUS Registers
Register
Address
Data
Type
Rep.
Description
Port Information
0x0100 to
0x0109
1 word
HEX Port 1 to 10 Link Status
0x0000: Link down
0x0001: 10M-Full-FC_ON (FC: Flow Control)
0x0002: 10M-Full-FC_OFF
0x0003: 10M-Half-FC_ON
0x0004: 10M-Half-FC_OFF
0x0005: 100M-Full-FC_ON
0x0006: 100M-Full-FC_OFF
0x0007: 100M-Half-FC_ON
0x0008: 100M-Half-FC_OFF
0x0009: 1000M-Full-FC_ON
0x000A: 1000M-Full-FC_OFF
0x000B: 1000M-Half-FC_ON
0x000C: 1000M-Half-FC_OFF
0xFFFF: No port
0x0200 to
0x021f
(port 1)
0x0220 to
0x023f
(port 2)
…
0x0320 to
0x033f
(port 10)
20 words ASCII Port 1 to 10 Medium
Port Description = “100TX,RJ45.” Or
“1000TX,SFP.”
Word 0 Hi byte = ‘1’
Word 0 Lo byte = ‘0’
Word 1 Hi byte = ‘0’
Word 1 Lo byte = ‘T’
…
Word 4 Hi byte = ‘4’
Word 4 Lo byte = ‘5’
Word 5 Hi byte = ‘.’
Word 5 Lo byte = ‘\0’
0x0400 to
0x0413
(port 1 to
10)
2 words
HEX Port 1 to 10 Tx Packets
Ex: port 1 Tx Packet Amount = 0x87654321
Word 0 = 8765
Word 1 = 4321
0x0440 to
0x0453
(port 1 to
10)
2 words
HEX Port 1 to 10 Rx Packets
Ex: port 1 Rx Packet Amount = 0x123456
Word 0 = 0012
Word 1 = 3456
0x0480 to
0x0493
(port 1 to
10)
2 words
HEX Port 1 to 10 Tx Error Packets
Ex: port 1 Tx Error Packet Amount = 0x87654321
Word 0 = 8765
Word 1 = 4321
0x04C0 to
0x04D3
(port 1 to
10)
2 words
HEX Port 1 to 10 Rx Error Packets
Ex: port 1 Rx Error Packet Amount = 0x123456
Word 0 = 0012
Word 1 = 3456