Programming the PFC using WAGO-I/O-
PRO
Using IEC 61131-3 programming, the ETHERNET Programmable Fieldbus
Controller 750-880, 750-880/025-000 can also utilize the function of a PLC in
addition to the functions of a fieldbus coupler. Creation of an application program
in line with IEC 61131-3 is performed using the programming tool WAGO-I/O-
PRO
.
Pos: 82.2 /Serie 750 (WAGO-I/O-SYSTEM)/In Betrieb nehmen/In WAGO-I/O-PRO programmieren/PFC mit WAGO-I/O-PRO progr.,Hinweis: Option „CoDeSys“ im Web-based Management-System aktivieren! @ 9\mod_1282111968039_21.doc @ 63800 @ @ 1
Note
Activate option "CoDeSys" in the web-based Management System for
programming!
Pay attention, the IEC 61131-3 programming of the controller via ETHERNET
requires that the check box
CoDeSys
be activated at the Website "Port
Configuration" (default).
You can, however, also connect the client PC and controller serially for
programming using a programming cable.
Pos: 82.3 /Serie 750 (WAGO-I/O-SYSTEM)/In Betrieb nehmen/In WAGO-I/O-PRO programmieren/PFC mit WAGO-I/O-PRO programmieren - Beschreibung Teil 2 @ 9\mod_1282112143230_21.doc @ 63803 @ @ 1
A description of programming using WAGO-I/O-
PRO
is not included in this
manual. The following sections, on the other hand, contain important information
about creating projects in WAGO-I/O-
PRO
and about special modules that you
can use explicitly for programming of the ETHERNET Programmable Fieldbus
Controller.
Explanations are also provided as to how the IEC 61131-3 program is transferred
and how suitable communication drivers are loaded.
Information
Additional Information:
For a detailed description of using the software, refer to the manual for the
"WAGO-I/O-
PRO
". This manual is located in the Internet under:
Documentation
WAGO-I/O-SYSTEM 759
WAGO-
I/O-PRO
759-333
1.
Start the programming tool at
Start \ Programs \ WAGO-I/O-
PRO
.
2. Under
File
/
New
create a new project
A dialog window then appears on which you can set the target system for
programming.
Pos: 82.4 /Serie 750 (WAGO-I/O-SYSTEM)/In Betrieb nehmen/In WAGO-I/O-PRO programmieren/Dialogfenster Zielsystemeinstellungen auswählen 750-880 @ 7\mod_1273482369868_21.doc @ 56260 @ @ 1
Figure 55: Dialog window for target system settings