WAGO-I/O-SYSTEM 750
Commissioning 127
750-880, 750-880/025-000 ETHERNET Programmable Fieldbus Controller
Manual
Version 1.0.1
Since communication for each protocol takes place via different ports, you can
have several protocols activated simultaneously; communication takes place via
these protocols.
Pos: 80.21.35 /Serie 750 (WAGO-I/O-SYSTEM)/In Betrieb nehmen/Feldbusknoten in Betrieb nehmen/BootP deaktivieren - Ende der Anleitung (Controller) @ 6\mod_1264493847995_21.doc @ 48694 @ @ 1
6. Click
on
SUBMIT
and then switch off the power to the controller
(hardware reset), or press down the mode selector switch. The protocol
settings are then saved and the controller is ready for operation.
If you have activated the MODBUS/TCP protocol, for example, you can now
select and execute required MODBUS functions using the MODBUS master too,
such as querying of the module configuration via register 0x2030.
If you have activated the WAGO-I/O-
PRO
for example, you can also program the
controller via ETHERNET link using WAGO-I/O-
PRO
in line with Standard
IEC-61131-3.