18
VERSION 10/2018
ORDER NUMBER DOC 2339321
.
Ensure that personal protective equipment (see Chapter
) is available and is used.
Ensure that all persons within the working area wear static dissipative shoes.
Footwear must comply with EN 20344. The measured insulation resistance must not
exceed 100 MΩ.
Ensure that during spraying, persons wear static dissipative gloves. The grounding
takes place via the spray gun handle or the trigger.
Protective clothing, including gloves, must comply with EN 1149-5. The measured
insulation resistance must not exceed 100 MΩ.
Ensure that there are no ignition sources such as naked flames, sparks, glowing wires,
or hot surfaces in the vicinity. No smoking.
Ensure that the pipe joints, hoses, equipment parts and connections are permanently,
technically leak-proof:
– Periodic preventative maintenance and service (replacing hoses, checking
tightness strength of connections, etc.)
– Regular monitoring of leaks and defects via visual inspection and odor testing,
e.g., daily before commissioning, at the end of work or weekly.
Ensure that maintenance and safety checks are performed regularly.
In the event of defects, immediately bring the device or system to a stop and arrange
to have repairs carried out immediately.
4.1.3 PERSONNEL QUALIFICATIONS
Hazard due to incorrect use of device!
Risk of death due to untrained personnel.
Ensure that the operating personnel has been instructed by the operator in accordance
with the operating manual and the operating instructions. The device must only
be operated, maintained and repaired by trained personnel. Refer to the operating
instructions for information about the required personnel qualifications.
4.2
SAFETY INSTRUCTIONS FOR THE PERSONNEL
Always follow the information in this manual, particularly the safety instructions and
the warning instructions.
Always follow local regulations concerning occupational safety and accident prevention.
In electrostatics application: Danger due to high-voltage field!
Danger to life.
Persons belonging to a risk group according to EMF guideline 2013/35/EU
(e.g., carriers of active implants), must not enter the high-voltage area.