103
VERSION 10/2018
ORDER NUMBER DOC 2339321
.
9.2.10.3 HIGH-PRESSURE FILTER, 530 BAR
1. Flush the pump and high-pressure filter in accordance with
Chapter
and with pump's operating manual. Flush using the
gun so that the flushing agent flows through the filter cartridge (F).
Maximize the flow (remove the nozzle, open the dosing valve if
necessary).
Filter
identification
Mobilux® EP2 *
Anti-seize paste*
53 MPa
530 bar
7687 psi
Filter installation position
Turned over
Loctite® 542 *
Loctite® 542 *
12
11
10
7
3
5
B_06836
1
21
2
2. Empty the pump in a controlled manner in accordance with
Chapter
and the pump's operating manual.
3. Place the grounded collection tank under the high-pressure filter.
4. Open ball valve (J).
5. Loosen union nut (A) with a size 70 wrench.
6. Unscrew the union nut (A) and lift slightly so that it does not get
dirty in the next step.
7. Remove the filter housing (B) with the union nut (A). The cone
spring (E) remains in the filter housing (B). If the O-ring (D) is not
damaged, it remains on the filter housing (B).
8. Remove the filter cartridge (F) and filter socket (G) from the filter
housing (B).
9. Clean all parts:
–Place the filter cartridge (F) and filter socket (G) in solvent.
Clean using brush.
–Fill the filter housing (B) approx. 1/3 full with solvent.
Close, wearing gloves, and shake well.
–Clean the distribution housing (H) using a brush.
10. If necessary, replace the O-ring (D) and/or filter cartridge (F).
For order no., see spare parts catalog.
11. Assemble all parts in reverse order. While doing so:
–Coat the thread of the distribution housing (H) with anti-seize
paste*.
–Coat O-ring (D) and pressure ring (C) with Mobilux® EP2 *.
–Observe the installation position of the filter cartridge (F):
Push the closed end with the filter identification ahead into
the filter housing (B).
–Make sure that the cone spring (E) is in the filter housing
(note the installation position). Press on the cone spring after
inserting the filter cartridge (F) and filter socket (G);
the spring action must be noticeable.
–Tighten the union nut (A) by hand.
12. Close ball valve (J).
13. Clean the spray gun's product filter in accordance with the spray
gun's operating manual.
14. Fill pump in accordance with Chapter
and the pump's
operating manual.
* For order no., see spare parts catalog.