Code Meaning
Cause
Fault rectification
26
Sensor A reversal
points
Stroke sensor A problem with
reversal points.
Calibrate A. Replace stroke sensor if
necessary.
27
Sensor B reversal
points
Stroke sensor B problem with
reversal points.
Calibrate B. Replace stroke sensor if
necessary.
30
Downward speed A
Pump A sags in downward stroke,
pump cavitating.
Check product supply.
31
Downward speed B
Pump B sags in downward stroke,
pump cavitating.
Check product supply.
32
Upward speed A
Pump A sags in upward stroke,
pump cavitating.
Check product supply. Leak check,
check piston valve.
33
Upward speed B
Pump B sags in upward stroke,
pump cavitating.
Check product supply. Leak check,
check piston valve.
40
Alarm password
The software is not enabled.
Enter software password.
WAGNER AG password
(only possible on PC).
41
Incorrectly adjusted
air pressure
Turbine speed too low.
Check turbine. Adjust air pressure
(WAGNER technician).
42
Incorrectly adjusted
air pressure
Turbine speed too high.
Check turbine. Adjust air pressure
(WAGNER technician).
61
Warning leakage A up The A fluid section has a slight leak
in the upward stroke.
Check circulation valve. / Schedule an
inspection of the A fluid section.
62
Warning leakage A
down
The A fluid section has a slight leak
in the downward stroke.
Check circulation valve. / Schedule an
inspection of the A fluid section.
63
Alarm leakage A up
The A fluid section has a large leak
in the upward stroke.
Check circulation valve. / Schedule
inspection of the A fluid section.
64
Alarm leakage A
down
The leak in the A-pump in the
downward stroke exceeds the error
limit.
Check circulation valve. / Schedule
inspection of the A fluid section.
65
Alarm leakage B up
The B fluid section has a slight leak
in the upward stroke.
Check circulation valve. / Schedule an
inspection of the B fluid section.
66
Alarm leakage B down The B fluid section has a slight leak
in the downward stroke.
Check circulation valve. / Schedule an
inspection of the B fluid section.
67
Alarm leakage B up
The B fluid section has a large leak
in the upward stroke.
Check circulation valve. / Schedule
inspection of the B fluid section.
68
Alarm leakage B down The leak in the B pump in the
downward stroke exceeds the error
limit.
Check circulation valve. / Schedule
inspection of the B fluid section.