52
VERSION 10/2018
ORDER NUMBER DOC 2339321
.
6.4.1 PNEUMATIC CONNECTIONS
Check whether the line pressure is sufficient. It must be between 0.6–0.8 MPa; 6–8 bar;
87–116 psi.
WARNING
Overpressure!
Risk of injury from bursting components.
The operating pressure must not exceed the value shown on the type plate.
Check whether efficient filter systems and condensate precipitators are available in
the air line.
The compressed air must be free of oil and water. Quality standard 7.5.4 according to
ISO 8573.1, 2010 must be observed:
7: Particle concentration 5 – 10 mg/m³
5: Humidity: pressure dew point ≤ +7 °C
4: Oil content ≤ 5 mg/m3
Every day, discharge all impurities and the condensate (if any) accumulated in the
system air filter.
WARNING
Brittle filter pressure regulator!
The tank on the filter pressure regulator becomes brittle through contact with solvents
and can burst. Flying parts can cause injury.
Do not clean the tank on the filter pressure regulator with solvents.
6.4.2 PRODUCT CONNECTIONS
Fit suction systems in accordance with operating manuals for pumps.
Connect high-pressure hose and gun to the TwinControl mixer unit as laid down in
the operating manual for the gun.