8.1.2 The Trigger Modes
Within each Sequence, the way of synchronization can be chosen individual. There are 4 different trigger
modes available:
1. Main Tempo Trigger (green field)
The time from Scene to Scene is constant while in Main Tempo Trigger.
2. The Tempo-Track Rate (blue field)
The time between Scenes can be varied from Scene to Scene using Tempo-Track Mode.
See also “The
V/T Editor”
current Scene name
Enter rate by pressing twice at
rate of music (this function can
also be entered to a “Hot Key”
see also chapter called “Hot
Keys”
create new Scene
(current Scene is template
for new Scene)
delete current Scene
single play/cycle Scene
change synchronization
mode by pressing
Scene speed rate in BPM (e.g. 120 BPM = 0.5s)
change synchronization
mode by pressing
Current time between Scenes - can be adjusted
directly here or into “Tempo-Track Editor”