Chapter 4. Monitoring System Operation
HS 2000 System Administrator’s Handbook
72
System Status
Comm Status parameters
Line Rate
Actual measured transmission clock rate. The line rate should stabilize at
+
1% of the data rate.
If this rate is 0, AppsView is not detecting a clock.
If this rate changes frequently, the clock source is unstable. Check the
cable type and your network interface equipment.
Comm State
Indicates the status of the port(s). The following table describes the dial
state associated with the state of the port indicated in the Comm State
field:
Port status dial states
State of port
Dial state
Idle
No call is in progress.
Dial tone
Network indicates ready to call.
Ringing
Network has sent alerting signal to calling site.
Busy
Network has sent busy signal to calling site.
Connected
Call is in progress; connection successful.
Ringback
Network has sent progress signal to calling site.
Error
Internal terminal adapter is not connected to ISDN.
Lockout site
Network has sent a disconnect signal to the calling site.