Fig. 10

4.1 DELIVERY  

 

Due to the weight of the appliance it may be necessary for 
two people to lift and attach the appliance to its mounting. The 
appliance is contained within a heavy-duty cardboard carton. 

Lay the carton on the floor with the writing the correct way up.

4.2 CONTENTS

Contained within the carton is:

• 

the boiler

• 

the wall bracket 

• 

carton template

• 

an accessories pack containing appliance service connections 
and washers

• 

the instruction pack containing the installation, servicing & user 
instructions, guarantee registration card and a 3-amp fuse.

4.3 UNPACKING

At the top of the carton pull both sides open – do not use a 
knife – unfold the rest of the carton from around the appliance, 
carefully remove all protective packaging from the appliance and 
lay the accessories etc. to one side. Protective gloves should 
be used to lift the appliance, the appliance back-frame should 
be used for lifting points.

4.4 PREPARATION FOR MOUNTING
 THE APPLIANCE

The appliance should be mounted on a smooth, vertical, sur-
face, which must be capable of supporting the full weight of 
the appliance. Care should be exercised when determining the 
position of the appliance with respect to hidden obstructions 
such as pipes, cables, etc.
When the position of the appliance has been decided – us-
ing the template supplied – carefully mark the position of the 

wall-mounting bracket (see fig.9) and flue hole (if applicable).

4.5 FITTING THE FLUE

The top flue outlet permits both horizontal and vertical flue ap

-

plications to be considered, alternatively, the Vokèra twin flue 

system can be utilised if longer flue runs are required. 

4.5.1 CONCENTRIC HORIZONTAL FLUE

(For concentric vertical flue, see 4.5.2).

(For twin flue applications, see 4.5.3).

The appliance can be used with either the Vokèra condensing 

60/100mm concentric flue system or the optional 80/125mm 

concentric flue system.

NOTE

These instructions relate 

only

 to the Vokèra condensing 

60/100mm concentric flue system. For specific details on the 

installation of the 80/125mm concentric flue system please refer 

to the instructions supplied. The appliance flue outlet elbow can 

be rotated through 360º on its vertical axis. In addition the flue 

may be extended from the outlet elbow in the horizontal plane 
(see 2.9). A reduction must also be made to the maximum length 
(see table below) when additional bends are used.

Reduction for additional bends

  

Bend            Reduction in maximum flue length for each bend

 

  45º bend 

1.0 metre (60/100) - 1.0 metre (80/125)  

  90º bend 

1.0 metre (60/100) - 1.5 metre (80/125) 

Horizonta

l flue terminals and accessories

 Part No. 

Description 

Length 

  

29450120 

Horizontal flue kit 

900mm 

   

Telescopic flue kit 

455/630mm

  522 

Plume management kit 

1370mm 

 29450123 

90-degree bend 

N/A 

 29450124 

45-degree bends (pair) 

N/A 

 29450125 

500mm extension 

500mm 

 29450126 

1000mm extension 

1000mm 

 29450127 

2000m extension 

2000mm 

 29450128 

Telescopic extension 

372/519mm

 529 

Wall bracket pack (5) 

208mm

Using the template provided (

A

), mark and drill a 125mm hole 

for the passage of the flue pipe. The hole should be drilled to 

ensure any condense fluid that forms, is allowed to drain back to 

the appliance (see fig. 11). The fixing holes for the wall-mounting 

bracket should now be drilled and plugged, an appropriate type 

and quantity of fixing should be used to ensure that the bracket 

is mounted securely. Once the bracket has been secured to 
the wall, mount the appliance onto the bracket.

FITTING THE TELESCOPIC HORIZONTAL FLUE KIT

In some instances It may necessary to cut the inner 60mm pipe 

of the flue bend at the point indicated (fig.12 pos. A) to allow 

for easier insertion to the boiler flue spigot.

FITTING THE HORIZONTAL FLUE KIT

Carefully measure the distance from the centre of the appliance 

flue outlet to the edge of the finished outside wall (dimension 

X). Add 65mm to dimension X to give you Dimension Y (see 

fig 11). Measure dimension Y from the terminal end of the con

-

centric flue pipe and cut off the excess ensuring any burrs are 

removed. Pass the concentric flue pipe through the previously 

drilled hole. Fit the flue bend to the boiler flue outlet and insert 

the concentric flue pipe into the flue bend ensuring the correct 

seal is made.

 

Using the clamp, gasket, and screws supplied, 

secure the flue bend to the appliance flue spigot. 

NOTE

Fit the internal (white) trim to the flue assembly prior to con

-

necting the flue pipe to the bend.

You must ensure that the entire flue system is properly sup

-

ported and connected. Seal the flue assembly to the wall using 

cement or a suitable alternative that will provide satisfactory 

weatherproofing. The exterior trim can now be fitted.

SECTION 4 - INSTALLATION

 Fig. 9

A

Terminal or 
extension

Outer clamps

Содержание Vibe 20 A G.C. N 41-094-84

Страница 1: ...NS TO BE RETAINED BY USER Vok ra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK Vibe High ef...

Страница 2: ...8 Mounting on a combustible surface 11 3A 9 Timber framed buildings 11 3A 10 Inhibitors 11 3A 11 Declaration of conformity 11 Installation Page 4 1 Delivery 12 4 2 Contents 12 4 3 Unpacking 12 4 4 Pr...

Страница 3: ...er has been designed to meet and exceed the very latest standards in gas central heating technology and if cared for will give years of reliable use and efficiency Please therefore take some time to r...

Страница 4: ...ating temperature selector move the selector clockwise to increase the heating outlet temperature or counter clockwise to reduce the tem perature range 40 C 80 C for standard central heating The autom...

Страница 5: ...t simultaneously 2 6 AUTOMATIC TEMPERATURE CONTROL The automatic temperature control function SARA permits the boiler when the heating temperature selector is set within 4 and 6 sector to automaticall...

Страница 6: ...I NEED TO CALL AN ENGINEER Ifyouthinkyourboilermayhavedevelopedafault pleasecontact yourinstallerorVok raCustomerServices 08443910999 UK or 056 7755057 ROI have all your details to hand including ful...

Страница 7: ...e ap plications These appliances are designed for use with a sealed system only consequently they are not intended for use on open vented systems This booklet is an integral part of the appliance It i...

Страница 8: ...bytheelectroniccircuittoensureflamestability at the burner Once successful ignition has been achieved the electronic circuitry increases the gas rate to 75 for a period of 15minutes Thereafter theboil...

Страница 9: ...Dry weight kg 26 28 2 5 Clearances Vibe 20A Vibe 25A Sides 12mm Top 150mm from casing or 25mm above flue elbow whichever is applicable Bottom 150mm Front 600mm 2 6 Connections Vibe 20A Vibe 25A Flow...

Страница 10: ...wall 300 mm P From a structure to the side of the vertical terminal 300 mm Q From the top of the vertical terminal to the roof flashing As determined by the fixed collar of the vertical terminal R To...

Страница 11: ...an unusually high water content it may be necessary to provide additional expansion capacity see 6 18 3 6 6 FILLING POINT A method for initial filling of the system and replacing water lost during ser...

Страница 12: ...is no requirement for a sheet of fireproof material to protect the wall 3 9 TIMBER FRAMED BUILDINGS If the appliance is to be fitted in a timber framed building it shouldbefittedinaccordancewiththeIns...

Страница 13: ...omplies with the local water authority regulations 3A 6 7 LOW PRESSURE SEALED SYSTEM An alternative method of filling the system would be from an independent make up vessel or tank mounted in a positi...

Страница 14: ...e see 2 9 Areduction must also be made to the maximum length see table below when additional bends are used Reduction for additional bends Bend Reduction in maximum flue length for each bend 45 bend 1...

Страница 15: ...ING THE REAR FLUE fig 14 rear flue outlet only Using the template provided mark and drill a 125mm hole for the passage of the flue pipe The hole should be drilled LEVEL to ensure any condense fluid th...

Страница 16: ...rminal 1 0 metre 359 Twin adapter kit N A 531 Pitched roof flashing plate N A 532 Flat roof flashing plate N A 0225815 Condensate drain kit N A 0225820 0 25m extension pair 50mm 0225825 0 5m extension...

Страница 17: ...iance flue outlet Remove the blanking plate located to the left of the appliance flue outlet and using the same screws install the air inlet plate B Using the hole in the exhaust connection manifold a...

Страница 18: ...e wire to NEUTRAL supply green yellow to EARTH connection Insertthesupplied3 AMPfuseintothefusedisolatororfusedplug Should the fly lead be unsuitable refer to 4 7 3 for details on how to connect the e...

Страница 19: ...nce service valves are open 5 6 INITIAL LIGHTING Ensure the electrical supply to the appliance is switched on Ensure any external controls are switched to an ON position and are calling for heat Move...

Страница 20: ...ilure to install and com mission the appliance to the manufacturers instructions will invalidate the warranty 5 13 INSTRUCTING THE USER Hand over all documentation supplied with this appliance includi...

Страница 21: ...from the pump assembly and remove the AAV assembly J Replace in the reverse order 6 7 1 TOP AUTOMATIC AIR RELEASE VALVE fig 29 Carry out component removal procedure as described in 6 4 Remove the AAV...

Страница 22: ...tly ease the fan assembly out of its location Once the assembly has been removed the burner K1 can be withdrawn from the heat engine Ensure the seals L1 is in good condition taking care to ensure it i...

Страница 23: ...s described in 6 4 Remove the locking pin Q1 that secures the cover R1 to the hydraulic manifold Using a hooked piece of wire carefully withdraw the by pass cartridge S1 Ensure all seals are in good c...

Страница 24: ...the ignition sequence com mences Ignition is sensed by the electronic circuit to ensure flame stability at the burner Once successful ignition has been achieved the electronic circuitry increases the...

Страница 25: ...it the plug fig 40 L2 and move the mode selector through position Remove the test probe from the test point and refit the sealing screw s and or cap IMPORTANT A GAS TIGHTNESS CHECK MUST BE CARRIED OUT...

Страница 26: ...as failed but no fault is in dicated a detailed continuity check will be required to trace the fault A visual inspection of components may also assist in locating the fault 7 7 3 POLARITY CHECK With t...

Страница 27: ...LICATIONS The appliance can be used with the following controls twin channel programmers The appliance can be used in conjunction with typical S Plan systems and Y Plan systems Please contact Vokera t...

Страница 28: ...sed JP5 Selection operating only heating JP6 Unused JP7 Unused JP8 Closed Unused LED Led 1 green working status or temporary stop Led 2 yellow CO 2 function ON Led 3 red boiler lock out brown CN3 blue...

Страница 29: ...INSTALLATION The entire installation including the meter must be purged and checked for gas tightness 9 6 2 GAS VALVE MAXIMUM SETTING Set the CO button at maximum see 10 3 1 once the maximum is obtai...

Страница 30: ...TO MINIMUM RATE In accordance with section 7 3 set boiler to operate at minimum rate to minimum load condition Allow sufficient time for combustion to stabilise YES Is CO 350ppm and CO CO2 ratio less...

Страница 31: ...commissioning checklist completed in full To instigate the boiler guarantee the boiler needs to be registered with the manufacturer within one month of the installation To maintain the boiler guarante...

Страница 32: ...nterlock Provided ALL SYSTEMS The system has been flushed and cleaned in accordance with BS7593 and boiler manufacturer s instructions Yes What system cleaner was used What inhibitor was used Quantity...

Страница 33: ...egister No Record At max rate CO ppm AND CO At min rate Where Possible CO ppm AND CO Comments Signature SERVICE 04 Date Engineer name Company name Telephone No Gas safe register No Record At max rate...

Страница 34: ...33...

Страница 35: ...34...

Страница 36: ...1HG enquiries vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 0999 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limite...

Отзывы: