Summary of Contents for 20014351

Page 1: ...COMBINATION STORAGE CYLINDER STOR C SOLAR INSTALLATION MANUAL ...

Page 2: ...nd cheap to run Technical Assistance Centres also stock any original spare parts that might be required This instruction manual contains important instructions and precautions that must be observed to ensure the trouble free installation and efficient functioning of your BERETTA STOR C combina tion storage cylinder Please accept our renewed thanks for your purchase Beretta RANGE The following symb...

Page 3: ...acking the product 10 Dimensions and weight 10 Handling 11 Place of installation 13 Installation in older systems and systems requiring modernisation 13 Water connections 14 Location of probes 16 Initial start up 16 Preparing for extended periods of disuse 18 Maintenance 18 Cleaning and removing internal components 19 4 RECYCLING DISPOSAL 20 Recycling disposal 20 5 TROUBLESHOOTING 20 ...

Page 4: ...ust be mixed with water in a percentage varying from 30 to 50 as instructed in the relevant BERETTA installation and maintenance manual b b Only fill the solar heating system with water and glycol premixed in the per centages specified in the BERETTA installation and maintenance manual b b This instruction manual is an integral part of the appliance It must be kept safe and must ALWAYS accompany t...

Page 5: ...e insulation and an elegant external casing reduce heat loss and improve efficiency A flange is provided for easy cleaning and maintenance and a magnesium anode is provided to prevent corrosion Excellent flexibility permits use in both high and low temperature systems Dimensions are extremely compact thanks to the clever combination of an inertial stor age cylinder and domestic hot water tank BERE...

Page 6: ...ure 10 Magnesium anode 11 Flange 12 Cylinder cover 13 Flange cover 14 Domestic hot water recirculation 15 Domestic hot water outlet 16 Domestic cold water in 17 Domestic hot water probe well 18 Vent valve fitting 19 Heating flow 1 high temperature 20 Boiler probe well 21 Heating return 1 high temperature 22 Auxiliary probe well 23 Solar collector outlet 24 Heating flow 2 low temperature 25 Solar c...

Page 7: ...6 92 kW Continuous production of domestic hot water 800 1000 l h Water draw in 10 minutes with mean T of 35 and main buffer tank at 80 C 515 550 l 70 C 500 515 l 60 C 415 450 l Maximum working pressure of domestic hot water tank 6 bar Maximum working temperature of domestic hot water tank 99 C Maximum working pressure of inertial storage cylinder 3 bar Maximum working temperature of inertial stora...

Page 8: ...Mod 1000 Mod 750 Fig 2 2 2 5 Accessories The following accessories are available to be ordered separately ACCESSORY CODE Control box SUN B 20009244 Control box SUN C 20009246 Water outlet and return kit top 6 5 m 20009197 Water outlet and return kit 11 m 20009196 Thermostatic mixer valve 1150529 24 l expansion vessel 1150509 35 l expansion vessel 1150519 ...

Page 9: ... for the water outlet and return kit EAF Domestic cold water inlet RL DHW recirculation UAC Domestic hot water outlet MC1 Outlet from boiler 1 high temperature MC2 Outlet from boiler 2 low temperature RC1 2 Return to boiler 1 2 RI2 SB Heating return 2 low temperature Inertial storage cylinder drain MI2 Heating flow 2 low temperature R Collector return M Collector outlet RE Sleeve for electric heat...

Page 10: ...wooden pallet The following items are delivered in a plastic bag inside the packaging instruction manual certificate of warranty and label with bar code spare parts catalogue hydraulic test certificate b b The instruction manual is an integral part of the combination storage cylinder Once located read it thoroughly and keep it safe DESCRIPTION MODEL STOR C 800 STOR C 1000 H Height 1870 2196 mm Ø D...

Page 11: ...age cylinder from the pallet Place a platform of about half the height of the pallet near the storage cylinder Make sure the platform is able to support the weight of the storage cylinder Remove the brackets then carefully rotate and slide the storage cylinder off the pallet on to the platform Make sure that the storage cylinder is per fectly stable and then remove the pallet Carefully rotate and ...

Page 12: ...ou wrap it around the storage cylinder With the insulation fitting snugly around the storage cylinder engage the zip slider and close the zip b The insulation must be at a temperature of at least 20 C in order to fit it If it is too cold warm it up before attempting to wrap it around the storage cylinder b Pull the edges of the insulation together above the zip as you close it in order to avoid br...

Page 13: ...onsible for any costs incurred to demolish masonry or other structures preventing or impeding free access to the space where the combination storage cylinder is to be installed When installing BERETTA STOR C combina tion storage cylinders in old systems or sys tems requiring modernisation always perform the following checks Make sure that the system is fitted with safety and control devices in acc...

Page 14: ... 75 E F G H B C D MC1 MI1 MI2 RI1 RI2 SB MC2 RC1 2 M R VS RL UAC EAF Fig 3 4 MC1 Outlet from boiler 1 Ø 1 1 4 F MC2 Outlet from boiler 2 Ø 1 1 4 F RC1 2 Return to boiler 1 2 Ø 1 1 4 F RI2 SB Heating return 2 Ø 1 1 4 M Inertial storage cylinder drain MI2 Heating flow 2 Ø 11 1 4 F M Collector outlet Ø 1 M R Collector return Ø 1 M RI1 Heating return 1 Ø 1 1 4 F MI1 Heating flow 1 Ø 1 1 4 F EAF Domest...

Page 15: ...he domestic hot water outlet tempera ture b If the pressure in the solar heating circuit drops do NOT top up with water but use the proper water glycol mix Risk of freezing b All piping collectors heat exchangers and other devices in the circuit must be subjected to proper hydraulic seal test ing b The choice of system components and the method of their installation are left up to the installer In...

Page 16: ...rectly flushed out and filled with water glycol mix and all air has been bled out of the circuit b b The domestic hot water tank must be filled and pressurised before the inertial storage cylinder is filled Fig 3 5 Fig 3 6 BERETTA STOR C combination storage cyl inders incorporate probe wells for fitting the solar controller and boiler probes Make sure that these probes are inserted all the way b b...

Page 17: ...nce the system has been started up per form the following checks Check that the flow rate in the solar heating circuit is equivalent to 30 l h for each m2 of collector area Check that the solar heating circuit has been properly bled Check that the cold pressure of the system is approximately 3 bar Check that the safety valve operates at 6 bar Check that all pipes in the water circuit have been ins...

Page 18: ...Centre if you encounter any prob lems in completing the above procedure Scheduled maintenance is essential for the safety efficiency and long working life of your com bination storage cylinder Proper maintenance also reduces energy consumption and ensures reliability over time Have your combination storage cylinder serviced either by a BERETTA Technical Assistance Centre or by a qualified professi...

Page 19: ...d the flange covers 2 Use a wrench to unscrew the bolts 4 fix ing the flange 5 in place and remove the flange taking care not to damage the seal 6 and magnesium anode 7 Clean inside the domestic hot water tank and remove any residues through the access hole Check the magnesium anode 7 for wear and replace it if necessary Once the cleaning operations have been com pleted refit all components follow...

Page 20: ...miter Fit a flow reducer Check and clean as necessary Check the pump The water temperature is low in the heat generator or solar heating system There are problems with the storage cylinder s thermostat The pump is malfunctioning There is lime scale or sludge in the tank Water temperature is low Check the setting and condition of the thermostat Check the setting and condition of the thermostat Chec...

Page 21: ...a T of 8 10 C There is lime scale or sludge in the tank Check and clean as necessary The flow rate is too high Reduce pump speed and turn the flow rate adjustment screw on the valve group to set a flow rate of 30l h per m2 of collector area The pump does not work even if the collector probe detects a collector temperature higher than that in the storage cylin der Maximum temperature has been excee...

Page 22: ......

Page 23: ......

Page 24: ...w berettaclima it Beretta is constantly improving its products and therefore reserves the right to modify the characteristics and specifications of the appliance described in this manual at any time and without prior notice The contents of this manual are not contractually binding on the manufacturer Cod 20014957 ...