The Vibe comprises a range of high-efficiency system boilers
with outputs of 20kW and 25kW. These appliances – by design
– incorporate electronic ignition, circulating pump, expansion
vessel, safety valve, pressure gauge and automatic by-pass.
The Vibe range is produced as room sealed, category II2H3P
appliances, suitable for internal wall mounting applications only.
Each appliance is provided with a fan powered flue outlet with
an annular co-axial combustion air intake that can be rotated
– horizontally – through 360 degrees for various horizontal or
vertical applications. The Vibe can also be used with the Vokèra
twin flue system.
The Vibe is approved for use with C13 & C33 type flue ap
-
plications.
These appliances are designed for use with a sealed system
only; consequently they are not intended for use on open
vented systems.
This booklet is an integral part of the appliance. It is therefore
necessary to ensure that the booklet is handed to the person
responsible for the property in which the appliance is located/
installed. A replacement copy can be obtained from Vokèra
customer services.
Fig. 3
General layout
1
Drain valve
2
Three porte valve actuator
3
Safety valve
4
Pump
5
Bottom auto air vent (AAV)
6
Main heat exchanger
7
Flues thermistor (NTC)
8
Fan assembly with mixer
9 Silencer
10
Flue gas analysis test point
11
Flue outlet & air intake
12
Top AAV
13 De-aerator
14
Spark Electrode - Sensing Electrode
15
Ignition transformer
16
Flow thermistor (NTC) - High limit thermostat
17
Expansion vessel
18
Pressure switch
19 Return thermistor (NTC)
20
Gas valve
21 Condense trap
R Heating return connection
F
Heating flow connection
G
Gas connection
INTRODUCTION
INSTALLATION AND SERVICING INSTRUCTIONS
R F G