67
3
4
6
7
Hook
APPLICATION
About a Fuse Box
Replacing the Fuse
Declination
Declination
body cover
body cover
Declination
Declination
body cover
body cover
Declination body cover
Declination body cover
Window
Window
Hook
Hook
Fuse box cover
Fuse box cover
Fuse box cover
Fuse box cover
Fuse
Fuse
Fuse
Fuse
Fuse
Fuse
In the AP mount, the electrical circuit board is protected by a fuse. It
is a rare case that a fuse is cut off in general use of the mount. If this
happens, you will need to replace the fuse with a fresh one.
1
Remove the declination body cover.
Open up the polar scope window on the declination body by sliding
down the shutter. While pushing down on the hook on the bottom of
the declination body, pull out the declination body cover by pinching the
hook and window hole with fingers .
2
Remove the batteries from the declination body. Do not disassemble the mount without removing the batteries. This may cause damage.
3
Remove the cover of the fuse box.
4
Pull out the fuse.
5
Push a new fuse into the fuse box to set.
6
Put the cover on the fuse box and install the batteries, if necessary.
7
Replace the declination body cover noting the direction of the hook
on the cover.
Specifications:
125V 1A Class-B (PES standard)
6mm dia. x 30mm