62
APPLICATION
Case 3: Changing the Manual Slow Motion Control Module for the R.A. Motor Module.
Declination
Declination
body
body
Declination body
Declination body
Window
Window
Declination body cover
Declination body cover
1
Remove the declination body cover.
Open up the polar scope window on the declination body by
sliding down the shutter. While pushing down on the hook on
the bottom of the declination body, pull out the declination
body cover by pinching the hook and window hole as shown
in the figure.
2
Remove the batteries from the declination body. Do not disassemble the mount without removing the batteries. This
may cause damage.
3
Loosen the two socket head cap screws on the declination body as shown in the figure with the 4mm Allen wrench.
Remove the declination body. Be sure to hold the declination body in hand securely while loosening the screws.
Hook
Hook
R.A motor module
R.A motor module
4mm
4mm
Allen wrench
Allen wrench
3mm
3mm
Allen wrench
Allen wrench
Electrical contact
Electrical contact
Electrical contact
Electrical contact
Polar axis body
Polar axis body
Manual slow motion
Manual slow motion
control module
control module
4
Loosen the three socket head cap screws on the manual slow motion
control module with the 3mm Allen wrench. Remove the manual slow
motion control module.
5
Attach the R.A motor module onto the polar axis body so that the
electrical contact faces to the outside as shown in the figure.
The internal joint electrical contact of the declination body is very
delicate. Take care not to touch with fingers or other objects.
Caution: