12
V3-205 Dispensing System Owner’s Manual
Section 4
Pre-Installation Requirements
VENTILATION
If the system is to be installed in an enclosed
space or in a cabinet, adequate ventilation must
be provided.
CAUTION
Failure to provide adequate
ventilation will cause system failure.
This unit is to be installed indoors only.
4
1
/
2
"
5
1
/
8
"
Available VIVREAU Grille
11
3
/
4
"
11"
3
/
8
"
4
5
/
8
"
2"
4
5
/
8
"
2"
PLEASE NOTE
All vents must open to fresh air
in a free and unobstructed area.
Front Ventilation
Showing ventilation
grilles cut in a standard
door panel
Cut-out detail for the
VIVREAU grille, shown in
a 23.5" (24") wide door
Side Ventilation
Ventilation grilles cut in the side of a
standard 24" cabinet. The grilles may
be fitted on either side, provided they
ventilate into a free, unobstructed area.
Base Ventilation
Ventilation grilles cut in the cabinet's base
panel and base plinth. Top ventilation will also
be required in either the side panels or a
cut-out in the top of the door.
Base Cutout
Ventilation can be made through the base of the cabinet, with the removal
of a narrow section of floor immediately behind the door. Trim with roll
edging strip. Cut-out size must not be less than 11.0" wide x 1.5" deep.
Ventilation Options
Содержание V3-205
Страница 4: ...4 V3 205 Dispensing System Owner s Manual...
Страница 6: ...6 V3 205 Dispensing System Owner s Manual Section 1 Safety Precautions...
Страница 8: ...8 V3 205 Dispensing System Owner s Manual Section 2 General Information...
Страница 16: ...16 V3 205 Dispensing System Owner s Manual Section 5 Operation...
Страница 24: ...24 V3 205 Dispensing System Owner s Manual Section 7 Troubleshooting NOTES...
Страница 25: ...V3 205 Dispensing System Owner s Manual 25 Section 7 Troubleshooting NOTES...
Страница 26: ...26 V3 205 Dispensing System Owner s Manual Section 7 Troubleshooting NOTES...
Страница 27: ...V3 205 Dispensing System Owner s Manual 27...