AC socket
Make sure all electrical devices are switched off before
plugging them.
When connecting an equipment or extension cord to
the AC socket of the generator, you must ensure the
following:
▪
The equipment and the extension cords are in good
condition. Defective equipment and extension cords
can cause electric shock;
▪
If an equipment starts operating abnormally, slows
down or stops suddenly, turn it off immediately.
▪
The power of the equipment may not exceed the
capacity of the generator. Never exceed the
maximum power of the generator. The maximum
power of the generator may not be used for a period
longer than half an hour;
Exceeding the time limit on the maximum charge
will slowly overload the generator and even
though you do not switch off the circuit breaker, this
process will shorten the life of the generator.
Make sure the generator is connected to the ground
terminal. When the electrical device is grounded, the
generator must also be.
To connect the equipment to the generator, proceed as
follows:
1. Plug the generator;
2. Plug the ESC switch;
3. Connect the AC plug;
4. Make sure that the AC pilot light (3B) is switched on;
5. You can switch on the electrical device;
The ESC switch should be switched off to increase
engine speed to the correct rotations per minute.
If the generator is connected to several loads or
electricity consumers, remember to connect first the
one with the highest current and last the one with the
lowest current.
3 in 1 switch
1 - Engine switch/ fuel shut off valve is in
"OFF"
position;
Engine switch/ fuel shut off valve is in "OFF" position.
Ignition system is off. Fuel circuit is off.
The mechanism will not work.
2
–
Engine switch/ fuel shut off valve /
Air intake shut-
off valves in
“ON” position
;
Ignition system is on. Fuel circuit is on. Air intake shut-
off valves on.
The engine can start.
3
–
Engine switch/ fuel shut off valve / Air intake shut-
off valves is in
“CHOCKE”
position;
Ignition system is on. Fuel circuit is on. Air intake shut-
off valves off.
The engine can start.
You don't need to shut-off the air intake valve
to start a hot engine.
Oil alert indicator light (Red)
When the oil level falls below the minimum level, the oil
alert indicator light (1B) lights up and the engine stops
automatically.
If the engine stops or does not start, set the switch
to the "ON" position and pull the recoil starter.
If the oil alert indicator light flashes or a few seconds,
the oil in the engine is insufficient. Add oil and start the
engine.
Содержание PRO-POWER VIGI1250
Страница 1: ...PT EN GERADOR INVERTER INVERTER GENERATOR ES FR GENERADOR INVERTER GROUPE LECTROG NE INVERTER VIGI1250...
Страница 6: ...6 DESCRI O DA FERRAMENTA E CONTE DO DA EMBALAGEM GERADOR INVERTER 1250 VIGI1250 Legenda A Legenda B...
Страница 22: ...22 DESCRIPCI N DE LA HERRAMIENTA Y CONTENIDO DEL EMBALAJE GENERADOR INVERTER 1250 VIGI1250 Leyenda A Leyenda B...
Страница 38: ...38 TOOL DESCRPITION AND PACKAGING CONTENT INVERTER GENERATOR 1250 VIGI1250 Figure A Figure B...
Страница 72: ...VIGI1250_REV01_MAI20...