CONFIDENTIAL
– This document is property of VITEC MULTIMEDIA, and may not be used or diffused to a third party without prior written approval.
LW Player User Guide v2.6
page 49 / 70
-
Open configuration file of the board (ActiveProfile.xml) in a text editor
-
Search for the strings:
<Property AccessFlags="512" Current="0" Default="0" Name="Show Info Window"/>
<Property AccessFlags="512" Current="94371840" Default="0" Max="125830200"
Min="0" Name="Info Window Coordinates"/>
-
Set values:
<Property AccessFlags="512" Current="1" Default="0" Name="Show Info Window"/>
<Property AccessFlags="512" Current="0" Default="0" Max="125830200" Min="0"
Name="Info Window Coordinates"/>
-
Save the configuration file.
-
Reopen the configuration in PlayerLW(m). When the configuration starts an information
window appears in the left upper corner of display.
-
Find genlock group in the information window.
-
If the board is genlocked the State is LOCKED.
NOTE:
If the board is run in 60fps, Secondary SD-SDI output works not synchronously with Primary HD-
SDI output and mustn’t be used as SDI-synchronisation output or configured as a source for genlock.