![Visonic PowerMaster-10 G2 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/visonic/powermaster-10-g2/powermaster-10-g2_quick-user-manual_1032851070.webp)
7. MAINTENANCE
70
D-304762 PowerMaster-10/30 G2 Installer's Guide
Option
Instructions
"
MOTION SENSORS
".
2.
Press
; the following screens will appear: "
Z01:Motion Sens
"
<location>
.
3.
Press
continuously to navigate to a different zone number.
4.
Press
; If the selected device is Tower-32AM PG2, the following screens will appear:
"
<OK MW ADJUST>
"
"<NEXT> TEST ONE"
.
To test the microwave range, go to step 5. To test a different microwave range, go to step 7.
5.
Press
; the following screen will appear: "
ACTIVATE MW NOW
".
6.
Activate the device; the screen will return to "
TEST ONE DEVICE
".
You can now repeat the procedure for another dual detector.
7.
Press
to select the sensitivity setting.
8.
Press
continuously to select between "
Minimum
" (default), "
Medium
" or "
Maximum
"
9a
. Press
; the panel will receive an acknowledge from the device that is indicated by a
black box next to the selected setting. Thereafter, the screen momentarily changes to
"
ACTIVATE MW NOW
" and then returns to the selected setting.
9b
. If you press
, the adjustment procedure ends.
Important
: The procedure mentioned above is for testing purposes only and does not change
the detector settings. The settings must be saved through the MODIFY DEVICES menu.
To test the shock detector:
1.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to navigate to
"
SHOCK SENSORS
".
2.
Press
; the following screens will appear: "
Zxx:Shk+AX+CntG3
"
1
<location>
.
3.
Press
continuously to navigate to a different zone number.
4.
Press
; the following screens will appear: "
Zxx ACTIVATE NOW
"
"SHOCK NOT
ACTIV
."
"CNTACT NOT ACTIV
"
"AUXIL. NOT ACTIV
".
Note:
The above screens are the full range of screens that can appear and indicate the
inputs that have not yet been activated. However, since there are various models of the
shock detector, not all of these screens will appear on some models.
5.
At this stage, activate each input of the shock detector in turn.
7. MAINTENANCE
7.1 Handling System Troubles
Fault
What it means
Solution
1-WAY
The control panel cannot configure or control
the device.
Battery consumption increases.
1. Make sure the device is physically present.
2. Check the display for device faults, for
example, low battery.
3. Use RF diagnostics to check the current
signal strength and during the last 24
hours.
4. Open the device cover and replace the
battery or press the tamper switch.
5. Install the device in a different location.
6. Replace the device.
AC FAILURE
There is no power to gas sensor
Make sure that the AC power supply is
connected properly
1
Depending on shock detector model, one of the following may appear instead: "
Zxx:Shk+AX
" / "
Zxx:Shk+CntG3
" /"
Zxx:Shk+CntG2
".