6. PERIODIC TEST
D-304762 PowerMaster-10/30 G2 Installer's Guide
69
Option
Instructions
CONTINUE
". During this time, the siren of the tested smoke sensor will sound for up to one
minute.
Press
to test the siren of the next smoke sensor.
When the sirens test is complete, the display reads "
SIREN TESTS END
". Press the
or the
button to confirm the test.
TEMPERATURE TEST
The control panel reads the temperature of the zone.
To display the temperature of zones on the control panel, press
. The control panel
reads the temperature of each zone. The display alternates between the temperature, the
sensor number and the sensor location, as in the following example: "
Z01 24.5
°°°°
C
" changes to
"
Z01:Temp. Sensor
" changes to "
Guest room
". Repeatedly click the
button to
review the temperature of each zone (by Temperature Sensor).
When the temperature of all zones has been reviewed, the display reads "
DEVICE TESTS
END
". Press the
or the
button to confirm the test and then move to the next
step to test the other devices.
TEST ALL DEVICES
You can test all devices in one procedure.
While in "
TEST ALL DEVICES
", press
to initiate the test.
The control panel now reads "
NOT ACTIVE NNN
". "
N
" indicates the number of enrolled
devices in the control panel that have not been tested. This number automatically drops one
count for every tested device.
When the "
NOT ACTIVE NNN
" screen appears, walk throughout the site to test the detectors
/ sensors or press any key of the selected handheld device to initiate the test.
After a device has been activated, the control panel reads "
Zxx IS ACTIVATED
" and the "
N
"
indicator drops one count.
Pressing
during the testing process will display details of each device that has not yet
been tested. The control panel reads the device number, followed by the device type (for
example, Contact Sensor, Motion Sensor or Keyfob) and followed by the device location. At
this stage, pressing any one of the following keys will open the following options:
1. Press
to view details of the next untested device.
2. Press
to exit the test process.
During testing, you can also check the signal strength indication of each device, (for further
details, refer to the device Installation Instructions).
After all devices have been tested, the control panel reads "
DEVICE TESTS END
".
TEST ONE DEVICE
→
→
→
→
CONTACT SENSORS
→
→
→
→
MOTION SENSORS
→
→
→
→
GLASSBREAK SENS.
→
→
→
→
SHOCK SENSORS
Select a specific device group you wish to test. For example, Motion Sensors.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to scroll through the
device families. Press
to enter the < device family > sub menu For example: "
MOTION
SENSORS
".
The following screens will appear: "
Xxx:<device name>
"
<location>
Where "
Xxx
" indicates the device number.
If there is no device, the following screen will appear: "
NO EXISTING DEV.
".
Press
to test the selected device. The following screen will appear: "
Z01 ACTIVATE
NOW
".
Walk throughout the site to test the detectors / sensors or press any key of the selected
handheld device to initiate the test.
During testing, you can also check the signal strength indication of each device, (for further
details, refer to the device Installation Instructions).
At the end of the test process the panel will revert to: "
TEST ONE DEVICE
".
To test the microwave range of the dual detector:
1.
Press
to enter the "
TEST ONE DEVICE
" sub menu and use
to navigate to