5. PROGRAMMING
44
D-304762 PowerMaster-10/30 G2 Installer's Guide
Notes:
1.
To comply with
EN
requirements, 1 hour or 2 hours must be selected.
2. For UL installations, set to “4 hours” or less.
3.
For UL/ULC Residential Fire and Burglary Installations, the wireless supervision window
shall be enabled. It shall be set to 4 hours or less for Fire Installations and it shall be set to
24h for Burglary Installations only.
63:NOT READY
Define that in case of a supervision problem (i.e. a device is "missing" - see "62: MISSING
REPRT") whether the system will continue to operate as
normal
or the system status will
become "Not Ready" (
upon missing
) for as long as the "Missing" trouble exists.
Options:
normal
(default) and
if missing dev.
64:MISS/JAM ALRM
Previously known as
"BELL/REP.OPT
"
"EN/UL standards" require that if a supervision (missing) or jamming trouble occurs during
AWAY arming, the siren will sound and the event will be reported as a tamper event.
Define whether the system will behave according to
EN standards
or as
normal
(default).
Note:
To comply with
EN
requirements "EN standard" must be selected.
65:SMOK FAST MIS
Determine that If the smoke detector does not report at least once within a time window of
200 seconds, a “MISSING” alert is initiated.
Options:
Disabled
(default) and
Enabled.
5.5.8 Configuring Miscellaneous Features
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 5.5.1.
Option
Configuration Instructions
91:USER PERMIT
User Permission enables you to determine whether access to the INSTALLER MODE requires
the user's permission or not. If you select
enabled
, the installer will be able to access the system
only through the user menu after the user code has been entered (see section 5.2).
Options:
disable
(default) or
enable
(default in UK).
Note:
To comply with
EN
requirements, "Enable" must be selected.
92:BATTERY TYPE
1
Define which type of battery pack is used for the system to supply proper charge current.
Options:
7.2V NiMH
(default) or
9.6V NiMH
(default in UK).
93:SOAK PERIOD
2
Define the period of time for the Soak Test.
Options:
Disable
(default),
7 days
,
14 days
or
21 days
.
Notes:
1. If set to one of the above pre-defined period of times, to be operational Soak Test mode
must also be set to “
Enable Test
” from the “02:ZONES/DEVICES” menu (see Section 5.4.7).
2. If a change is made to the period of time of the Soak Test while the zone is currently being
tested, this will restart the Soak Test.
3. The start of the Soak Test period
is defined in the factory from 9 AM (09:00).
5.6 Communication
5.6.1 General Guidance – "Communication" Flow-Chart & Menu Options
The COMMUNICATION menu enables you to configure and customize the communication and reporting of alarm,
troubles and other system events for monitoring companies or private users according to your local requirements and
personal preferences. PowerMaster offers a variety of communication means including telephone PSTN landline,
Cellular GSM, GPRS or SMS and IP via broadband internet connection.
1
Refers to PowerMaster-30 G2 only
2
Soak Test is not applicable for UL installations