Installation

8

 

53

5.

Install the UV lamp. Refer to 

Section 4.1

.

6.

When all plumbing connections are complete, slowly turn on the water supply and check for leaks. The most likely cause 
of leaks is from the O-ring seal. In case of a leak, shut water off, drain cell, remove the retaining nut, wipe the O-ring and 
threads. Clean and re-install.

7.

Once it is determined that there are no leaks, plug the system into the ground fault interrupter and check controller to 
ensure the system is operating properly. The controller should illuminate without any alarms. 

Note: DO NOT look directly at the glowing UV lamp. 

8.

Allow the water to run for a few minutes to clear any air or dust that may be in the chamber.

Note: When there is no flow, the water in the cell will become warm, as the UV lamp is always on. To remedy this, run a 

cold water tap anywhere in the house for a minute to flush out the warm water. 

3.2 Disinfection Procedure

UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water. As UV 
does not provide a disinfection residual, it is imperative that the entire distribution system located after the UV be chemically 
disinfected to ensure that the plumbing system is free from any bacteriological contaminants. The disinfection process must 
be performed immediately after the UV unit is installed and repeated thereafter whenever the UV is shut down for service, 
without power, or inoperative for any reason. The procedure for sanitizing the plumbing system is readily accomplished as 
follows:

Figure 5 Drip Loop

•   

Ensure the controller is 
plugged in for entire 
disinfection process.

1

2

2

1

2

2

2

•   

Shut off the water supply.

•   

Close each faucet.

3

•   

Remove filter cartridge(s).

•   

Pour 2 cups of household 
bleach solution into the filter 
housing(s).

Note: DO NOT use Hydrogen 
Peroxide.

4

      Household 5.25%
       Bleach Solution

BLEACH

x2

2

1

Funcionamiento

Sección 5

Funcionamiento

5.1 Sistemas básicos que incorporan controladores BA-ICE-C y BA-ICE-CL

5.1.1 Vida restante de la lámpara (días)

 El controlador registra el número de días de funcionamiento de la lámpara y el controlador. La pantalla predeterminada 

indica la vida total restante de la lámpara (en días). El controlador seguirá contando el número de días que quedan para que 
haya que sustituir la lámpara (de 365 días a 1 día). Al llegar a “0” días, el controlador mostrará 

 y emitirá un chirrido 

intermitente (1 segundo encendido, 5 segundos apagado) para indicar la necesidad de cambiar la lámpara. 

5.1.2 Interpretación del código "A3"

 

APLAZAMIENTO

: cuando aparece en la pantalla LED el mensaje de fin de la vida útil de la lámpara o "A3", la 

alarma acústica se puede aplazar hasta 4 veces separadas. El retardo esta diseñado para que tenga tiempo de responder 
a la alarma mientras consigue otra lámpara UV. No tiene más que mantener pulsado durante 5 segundos el botón de 
reinicio del temporizador, que está situado en la parte izquierda del controlador. Cada vez que se pulse el botón de reinicio 
del temporizador, la alarma del controlador se aplazará siete días. Una vez transcurrido el plazo de 7 días, la alarma solo 
se podrá silenciar sustituyendo la lámpara UV y reiniciando de forma manual el temporizador del controlador (consulte la 

Sección 4.1

).

5.1.3 Reinicio de la vida de la lámpara

Consulte 

Sección 4.1

.

Nota: Aunque la alarma del sistema se puede aplazar durante un período de tiempo, es importante que se responda 

a todas y cada una de las condiciones de alarma, porque indican que existe un posible problema en el sistema que 
debería corregirse.

5.1.4 Número total de días de funcionamiento

 El controlador también indica su tiempo total de funcionamiento. Para obtener esta lectura, pulse una vez el botón. 

El tiempo total del funcionamiento del controlador aparecerá indicado de forma numérica en días. Esta información seguirá 
apareciendo durante diez segundos; después volverá a aparecer la pantalla predeterminada con la vida restante de la 
lámpara. Tenga en cuenta que este valor no se puede reiniciar.

5.1.5 Fallo de lámpara (pantalla en blanco)

 Cuando el sistema detecte un FALLO DE LÁMPARA UV (no habrá corriente en la lámpara), la pantalla se quedará 

en blanco 

 (no aparecerá la pantalla predeterminada de VIDA RESTANTE DE LA LÁMPARA) y el sistema emitirá un 

tono audible intermitente (1 segundo encendido,1 segundo apagado). El sistema permanecerá en este estado hasta que 
la condición se corrija.

A D V E R T E N C I A

El avanzado sistema de advertencia se ha instalado para ofrecer una protección óptima contra la contaminación microbiológica en el agua. 

NO

 haga caso omiso 

de las señales de advertencia. La mejor forma de garantizar el funcionamiento óptimo de UV es que una agencia de pruebas reconocida realice análisis 
microbiológicos de forma periódica.

Содержание VH200

Страница 1: ...f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canadá N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 solo EE UU y Canadá t 31 73 747 0144 solo Europa f 1 519 763 5069 correo electrónico info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail i...

Страница 2: ...reclamación bajo garantía necesitará su factura original o bien deberá haber completado y enviado su tarjeta de registro de producto por correo postal o en línea Cobertura específica de la garantía La cobertura de la garantía es específica de la gama de productos de VIQUA La cobertura de la garantía está sujeta a las condiciones y limitaciones establecidas en la sección Condiciones y limitaciones ...

Страница 3: ...l if you are in doubt as to whether the outlet is properly grounded DO NOT modify the plug provided with this system if it does not fit in the outlet have a proper outlet installed by a qualified electrician DO NOT use any type of adapter with this system GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electrical Code NFPA 70 and to provide additional protection from the ri...

Страница 4: ...r yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations CFR requirements including Title 21 Chapter 1 Subchapter J Radiological Health Re...

Страница 5: ...uales se llene de cloro lejía antes de que el agua salga del sistema UV Para funcionar de manera eficaz el sistema de desinfección debe tener un sistema de distribución libre de bacterias Consultar la Sección 3 2 Posible entrada de sedimentos a través del pre filtro Analice el agua de suministro para descartar la turbiedad es posible que necesite un filtrado escalonado para recoger todos los sedim...

Страница 6: ...fection System Note UV system should be the final piece of treatment equipment Optional flow restrictor Note Mandatory for NSF credited systems Optional water softener To drain Optional by pass assembly Optional by pass assembly Optional by pass assembly Optional solenoid valve Hot water pipes Cold water pipes Customer supplied GFCI circuit to match voltage Water meter Main water shut off 5 Micron...

Страница 7: ...2 segundos durante las condiciones de bajo nivel de UV Nota Niveles de UV de APLAZAMIENTO para aplazar temporalmente la alarma acústica y reactivar la válvula de solenoide si se ha instalado durante una alarma de nivel bajo de UV mantenga pulsado el botón de reinicio del temporizador durante cinco segundos Con esto se silenciará la condición de alarma acústica y se activará la salida de solenoide ...

Страница 8: ... que sustituir la lámpara de 365 días a 1 día Al llegar a 0 días el controlador mostrará y emitirá un chirrido intermitente 1 segundo encendido 5 segundos apagado para indicar la necesidad de cambiar la lámpara 5 1 2 Interpretación del código A3 APLAZAMIENTO cuando aparece en la pantalla LED el mensaje de fin de la vida útil de la lámpara o A3 la alarma acústica se puede aplazar hasta 4 veces sepa...

Страница 9: ...are present Replace the UV lamp annually or biennially if seasonal home use to ensure maximum disinfection Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures N O T I C E Reset lamp life timer after lamp replacement Refer to Section 5 1 3 Refer to www lamprecycle org for lamp disposal Do not use water during replacement of UV lamp 5...

Страница 10: ...ED display will read once again 10 51 Maintenance Procedimiento Nota Tras reemplazar la lámpara UV o la vaina tubular de cuarzo realice el procedimiento de desinfección y consulte la Sección 3 2 1 Drene la cámara usando el puerto de drenaje 2 1 2 3 Quite la tuerca de retención el muelle flotante y la junta tórica de la parte inferior 3 1 2 Quite la tuerca de retención y la junta tórica de la parte...

Страница 11: ... la vaina tubular de la lámpara Esta capa debe retirarse porque reduce la cantidad de luz UV que llega al agua reduciendo de este modo el rendimiento de la desinfección Si la vaina tubular no puede limpiarse deberá reemplazarse por otra Requisitos previos Cortar el suministro de agua y drenar todas las líneas Quitar la lámpara UV Consulte Sección 4 1 1 Corte la línea de agua de la cámara y libere ...

Страница 12: ...or de intensidad UV de 254 nm tenga en cuenta que la introducción de la solución de lejía requerida para efectuar la desinfección provocará una condición temporal de bajo nivel de UV Esto se debe a que la lejía enturbia físicamente el agua no potable Una vez que la lejía circule por el sistema la condición de alarma volverá al estado normal Durante el proceso de desinfección la condición de alarma...

Страница 13: ...optimum protection against microbiological contamination in water DO NOT disregard the warning signals The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on a regular basis Instalación 5 Instale la lámpara UV Consulte Sección 4 1 6 Cuando se hayan realizado todas las conexiones de tuberías conecte el suministro de agua lentame...

Страница 14: ...tes the UV level is still within a safe level however cleaning or lamp sleeve replacement may soon be required to Indicates the UV level is nearing the point of unsafe UV intensity UV system should be immediately serviced Indicates the UV level has now reached a level that is unsafe At this level the water should not be consumed The system water supply should be examined to determine the reason fo...

Страница 15: ...oque un peligro de incendio Es muy recomendable usar bucles de goteo en los cables conectados al controlador Consulte Figura 5 El sistema de agua completo incluidos los depósitos de presión o agua caliente se deben esterilizar antes de la puesta en marcha Para ello enjuague con cloro lejía doméstica para destruir toda contaminación residual Consulte Sección 3 2 El sistema de desinfección está dise...

Страница 16: ...tem should not be installed on a circuit which is incorporated into a light switch Lamp Failure Alarm on New Lamp Loose connection between lamp and connector Disconnect lamp from connector and reconnect ensuring that a tight fit is accomplished Moisture build up in connector may keep lamp and connector from making a solid connection Eliminate chance of any moisture getting to the connector and or ...

Страница 17: ...l debido la exposición a rayos UV es recomendable usar accesorios metálicos y canalización de cobre de al menos 25 4 cm en la salida de la cámara UV AVISO La lámpara UV en el interior del sistema de desinfección tiene una clasificación nominal con una vida eficaz de aproximadamente 9000 horas Para garantizar una protección continua reemplace la lámpara UV una vez al año Los niños no deben usar el ...

Страница 18: ...surización segura Este símbolo indica que se requiere el uso de botas de seguridad Este símbolo indica que el sistema está bajo presión Este símbolo indica que el operador debe leer toda la documentación disponible para realizar los procedimientos requeridos Este símbolo indica que existe peligro de exposición a rayos UV Se debe usar protección adecuada Este símbolo indica que el fontanero debe us...

Страница 19: ...rcionarle años de funcionamiento sin problemas con un mínimo mantenimiento para proteger su agua potable contra contaminantes microbiológicos Para garantizar la continua desinfección del agua las lámparas UV se deben reemplazar cada año por repuestos VIQUA de fábrica Las lámparas VIQUA son fruto de un extenso desarrollo que ha resultado en una plataforma de desinfección altamente eficaz con un ren...

Страница 20: ...e date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year Limited Warranty for UV lamps Sleeves and UV Sensors VIQUA warrants UV lamps sleeves and UV sensors to be free from defects in material and workmanship for a period of one 1 year from the date...

Страница 21: ...This page intentionally left blank ...

Страница 22: ...This page intentionally left blank ...

Страница 23: ...This page intentionally left blank ...

Страница 24: ...f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canadá N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 solo EE UU y Canadá t 31 73 747 0144 solo Europa f 1 519 763 5069 correo electrónico info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail i...

Отзывы: